ELECTRICAL
ExTENSION CORDS
Use only 3-wire extension cords that have 3-prong ground-
ing plugs and 3-pole receptacles that accept the tool’s plug. 
When using a power tool at a considerable distance from the 
power source, use an extension cord heavy enough to carry 
the current that the tool will draw. An undersized extension 
cord will cause a drop in line voltage, resulting in a loss of 
power  and  causing  the  motor  to  overheat.  Use  the  chart 
provided below to determine the minimum wire size required 
in an extension cord. Only round jacketed cords listed by 
Underwriter's Laboratories (UL) should be used.
**Ampere rating   (on tool faceplate)
 
0-.0 
.1-3.4 
3.5-5.0 
5.1-7.0  7.1-1.0   1.1-16.0
Cord Length  
Wire Size (A.W.G.)
  5' 
16 
16 
16 
16 
14 
14
  50' 
16 
16 
16 
14 
14 
1
  100' 
16 
16 
14 
10 
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
When working with the tool outdoors, use an extension cord 
that  is  designed  for  outside  use.  This  is  indicated  by  the  
letters “WA” on the cord’s jacket.
Before  using  an  extension  cord,  inspect  it  for  loose  or  
exposed wires and cut or worn insulation.
WARNING:
Keep the extension cord clear of the working area. 
Position the cord so that it will not get caught on 
lumber, tools or other obstructions while you are 
working with a power tool. Failure to do so can 
result in serious personal injury.
WARNING:
Check  extension  cords  before  each  use.  If 
damaged replace immediately. Never use tool with 
a damaged cord since touching the damaged area 
could cause electrical shock resulting in serious 
injury.
ELECTRICAL CONNECTION
This tool is powered by a precision built electric motor. It 
should be connected to a 
power supply that is 120 V, 60
Hz, AC only (normal household current). Do not operate 
this tool on direct current (DC). A substantial voltage drop 
will cause a loss of power and the motor will overheat. If the 
tool does not operate when plugged into an outlet, double 
check the power supply.
SPEED AND WIRING
The no-load speed of this tool is approximately 10,000 RPM. 
This speed is not constant and decreases under a load or 
with lower voltage. For voltage, the wiring in a shop is as 
important as the motor’s horsepower rating. A line intended 
only for lights cannot properly carry a power tool motor. Wire 
that is heavy enough for a short distance will be too light for 
a greater distance. A line that can support one power tool 
may not be able to support two or three tools.
GROUNDING INSTRUCTIONS
In  the  event  of  a  malfunction  or  breakdown,  grounding 
provides  a  path  of  least  resistance  for  electric  current  to 
reduce  the  risk  of  electric  shock.  This  tool  is  equipped 
with  an  electric  cord  having  an  equipment-grounding  
conductor and a grounding plug. The plug must be plugged 
into a matching outlet that is properly installed and grounded 
in accordance with all local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet, 
have the proper outlet installed by a qualified electrician. 
Improper connection of the equipment-grounding conductor 
can result in a risk of electric shock. The conductor with 
insulation having an outer surface that is green with or with-
out yellow stripes is the equipment-grounding conductor. If 
repair or replacement of the electric cord or plug is neces-
sary, do not connect the equipment-grounding conductor 
to a live terminal.
Check with a qualified electrician or service personnel if the 
grounding instructions are not completely understood, or if 
in doubt as to whether the tool is properly grounded.
Repair or replace a damaged or worn cord immediately.
This tool is intended for use on a circuit that has an outlet 
like the one shown in figure 1. It also has a grounding pin 
like the one shown. 
Fig. 1
GroundinG 
Pin
120 V Grounded outlet