Cabletron Systems TRMMIM 用户手册

下载
页码 120
Monitoring Hub Performance
2-23
Using the TRMMIM Hub View
Errors
The total number of errors detected by the selected station port since the device 
was last reset.
Frames
The total number of frames transmitted by the selected station port.
Bytes
The total number of bytes transmitted by the selected station port.
Line
The count of line errors detected by the selected station. This error indicates a 
non-data bit between the starting and ending delimiters of data, or a frame check 
sequence error.
Burst
The count of burst errors detected by the selected station port. This error indicates 
a bit information-encoding error where there are no transitions between 0 and 1 
over five half-bit times.
AC
The number of frames containing errors in the A or C bits detected by the selected 
station port.
Abort
The number of times the selected station has transmitted abort sequences during 
transmission.
Internal
The number of recoverable internal errors detected by the selected port, 
indicating that its attached station is in marginal operating condition.
Lost Frames
The number of frames that the selected station has transmitted that have not 
returned because the Timer – Return to Repeat (TRR) timer has expired.
Congest
The number of times the selected station has not been able to copy a frame 
addressed to it because of a lack of internal buffering.
NOTE
When a device is reset, statistics windows and/or statistics displays in the Hub View may 
display very large numbers for one polling interval. This is due to the resetting of the 
counters.