RECHARGEABLE BATTERY
4. 
Unplug charger. Remove the battery pack 
by sliding out (See Figure 3).
5. 
Place the battery pack in the tool and be 
certain that it is inserted fully into the tool 
cavity until it “clicks” into place.
The charger is designed to use standard house-
hold 120 volt 60 Hz power
1. 
Plug cord from charger into charger base. 
(See Figure 1)
The battery pack is not fully 
charged at the factory. Before 
attempting to charge the bat-
tery pack, thoroughly read all 
Safety Instructions.
2.  Plug the charger into any standard 120 
Volt 60 Hz electrical outlet. Important: 
Do not charge by means of an engine 
generator or DC power source. Use only 
120V AC.
3. 
Slide the charger onto the battery pack as 
shown in Figure 2. The LED will light up,  
Let the battery pack charge until red LED 
turns off.  After the initial charge, under 
normal usage, your battery pack should 
be fully charged in 3 to 9 hours.
IMPORTANT CHARGING NOTES
1.  After normal usage, your battery pack 
should be fully charged in 3 to 9 hours. If 
the battery pack is run-down completely, 
it may take up to 9 hours to become fully 
charged. Your battery pack was sent from 
the factory in an uncharged condition.  
For best performance charge battery until 
red LED turns off. Allow the battery to 
cool down 30 minutes before charging 
after using the trimmer/edger.  NOTE: A 
hot battery placed in the charger will not 
charge.
2.  DO NOT charge the battery pack in an 
air temperature below 40°F (4,5 °C) or 
above 105°F (40,5 °C). This is important 
and will prevent serious damage to the 
battery pack. Longest life and best per-
formance can be obtained if battery pack 
is charged when air temperature is about 
75°F (24°C).
3.  While charging, the charger may hum 
and become warm to touch. This is a 
normal condition and does not indicate a 
problem.
4. 
If the battery pack does not charge prop-
erly
•  Check current at receptacle by plugging 
in a lamp or other appliance.
•  Check to see if receptacle is connected 
to a light switch which turns power off 
when you turn out the lights.
•  Move charger and battery pack to a 
surrounding air temperature of 40°F 
(4,5°C) to 105°F (40,5 °C)
• 
If the receptacle and temperature are 
OK, and you do not get proper charging 
contact DESA Power Tools.
5.  The battery pack should be recharged 
when it fails to produce suffi cient power 
on jobs which were easily done previ-
ously. DO NOT CONTINUE using 
product with its battery pack in a depleted 
condition.
6.  To prolong battery life, avoid leaving 
the battery pack on charger for extended 
periods of time (over 30 days without 
use). Although overcharging is not a 
safety concern, it can signifi cantly reduce 
overall battery life.
7.  The battery pack will reach optimum 
performance after being cycled 5 times 
during normal usage. There is no need to 
run the batteries down completely before 
recharging. Normal usage is the best 
method of discharging and recharging the 
batteries.
Figure 1 - Plug Charger into Base
Figure 3 - Remove Charger
CHARGING BATTERY
Figure 2 - Sliding Charger onto  Battery
EN
GLI
S
H