Husqvarna 536LiHD60X 用户手册

下载
页码 24
20 – English
MAINTENANCE
Troubleshooting schedule
Control panel
Troubleshooting takes place from the keypad.
Troubleshooting the battery and/or the battery charger during charging.
Battery
Battery charger
LED display
Possible faults
Possible action
Green activate LED flashing.
Low battery voltage.
Charge the battery
Error LED flashes.
Overload.
The cutting attachment is jammed. 
Release the cutting attachment. 
Temperature deviation
Allow the machine to cool down.
The power trigger and the activate 
button are pressed at the same time.
Release the power trigger and the 
machine is active.
The machine does not run
Dirt in battery connectors.
Clean with compressed air or a soft 
brush.
Error LED is lit with red light. 
Service
Contact your service agent.
LED display
Possible faults
Possible action
Green activate LED flashing.
Low battery voltage.
Charge the battery
Error LED flashing
Temperature deviation
Use the battery in surroundings 
where temperatures are between -10 
°C and 40 °C.
Over voltage
Check that the mains voltage 
corresponds with that stated on the 
rating plate on the machine.
Remove the battery from the battery 
charger.
Error LED is lit
Cell difference too much (1V)
Contact your service agent.
LED display
Possible faults
Possible action
Error LED flashing
Temperature deviation
Use the battery charger only when the 
surrounding temperature is between 5 
°C and 40 °C.
Error LED is lit
Contact your service agent.