Error Messages
An error message appears in the display when an error in operation occurs, or if an operation cannot be processed correctly. 
When this occurs, continue by following the instructions indicated in the error message.
coE (MIDI Communication Error)
fig.coE
Situation:
There is a problem with the MIDI cable 
connected to the JV-1010’s MIDI IN connector or 
with an external device. However, this message 
is also displayed when the power for the 
external device is turned off.
Action:
Check to make sure the MIDI cable is firmly and 
properly connected. Otherwise confirm that 
there is no short in the MIDI cable (try switching 
the MIDI cable to check this).
bFL (MIDI Buffer Full)
fig.bFL
Situation:
More MIDI messages were received in a short 
time than could be processed correctly.
Action:
Reduce the amount of MIDI messages that are 
transmitted.
cSE (MIDI Check Sum Error)
fig.cSE
Situation:
A system exclusive message that was received 
had an incorrect check sum value.
Action:
Correct the check sum value.
rdE (Receive Data Error)
fig.rdE
Situation:
A system exclusive message was not properly 
received. Repeated appearance of this same 
error message means that there is a problem 
with the MIDI message. 
Action:
Check the content of the received system 
exclusive message.
noP (No Patch)
fig.noP
Situation:
If no expansion board is installed, then an 
expansion board patch or rhythm set is specified 
from the external MIDI device.
Action:
Reselect the patch and rhythm set.
und (User Memory Damaged)
fig.und
Situation:
USER
 data has been damaged.
Action:
Restore the factory settings with the Factory 
Reset procedure.
btL (Battery Low)
fig.btL
Situation:
Battery power used for saving parameter 
settings has been used up.
Action:
Take the JV-1010 to your dealer or nearby 
Roland Service to have the battery exchanged.