National Instruments SCC-LP02 用户手册

下载
页码 18
© National Instruments Corporation
5
SCC-LP Series Lowpass Filter Modules User Guide
The signal source can be floating or ground-referenced. The SCC-LPXX 
input circuitry includes high-impedance bias resistors typically required for 
floating sources. Therefore, floating signal sources do not require external 
bias resistors connected to ground.
Note
For floating signal sources in high-noise environments, connect the negative 
terminal of the signal source to the AI GND terminal on the SC-2345 screw-terminal block 
to reduce common-mode noise.
Figure 1.  SCC-LPXX Signal Connections
For information about configuring the SCC-LPXX module using 
NI-DAQmx, refer to the SCC Quick Start Guide.
AI ()
AI (X+8)
SCC-LP
+
E Series DAQ Device
+
+
+
Signal source may be floating or ground-referenced.
10 M
Ω 
10 M
Ω 
AI SENSE
1
3
4
2
AI GND
Fourth-Order
Butterworth 
Lowpass
Filter
1 k
Ω 
1 k
Ω 
1 k
Ω 
1 k
Ω 
Fourth-Order
Butterworth 
Lowpass
Filter
Signal 
Sources