Toshiba e-Studio160 服务手册

下载
页码 239
December 2002 TOSHIBA TEC
1 - 93
e-STUDIO160/200/250 ADJUSTMENT
: Turn the transfer guide bias ON.
Measure the transfer guide bias at the following two points:
Important:
The settings and conditions of the digital tester to be used for measurement are as
follows:
Function switch: DC
Full scale:
1000V
Remark:
The digital tester to be used should have an input resistance
value of 10M
Ω
 or more.
Measurement value: +375
±
20V
To measure on the pinch roller:
CLEAR/STOP
START
01-11-02
To measure on the paper guide plate:
From preceding page
: Turn the transfer guide bias OFF.
: End the output test.
01-11-03
CANCEL
CANCEL
Power OFF
Frame grounding
 terminal
Pinch roller
 terminal
Frame grounding
 terminal
 terminal
Paper guide plate