e-STUDIO160/200/250 ADJUSTMENT ITEMS
1 - 12
December 2002 TOSHIBA TEC
Scan image processing parameter  600 DPI
Code
620
621
622
693
694
695
Factor
Image
quality
Image
quality
Image
quality
Density
Adjustment item
No. of units: HPF table number
0: Use of default value
1: Text/Photo mode
2: Photo mode
3: For Text mode
4 - 9: Unused
No. of tens: Filter combination intensity
0: Use of default value
1 - 9: Filter combination intensity
Ditto
Ditto
Range correction on original set on the
ADF or RADF.
Set whether the value of the background
peak and text peak are fixed or not.
If they are fixed, the range correction is
performed with standard values.
The values of the background peak and
text peak affect the reproduction of the
background density and text density re-
spectively.
The number of units: Data while automatic
density is selected.
The number of tens: Data while manual
density is selected.
Background peak
Text peak
1: fixed
fixed
2: varied
fixed
3: fixed
varied
4: varied
varied
Image
mode
PPC
PPC
PPC
PPC
Image
quality
mode
Text/Photo
Photo
Text
Text/Photo
Photo
Text
Default
1
2
3
12
12
44
Acceptable
value *1
0-99
The larger the  intensity
coefficient the stronger  the
intensity.
0-99
0-99
11-14
21-24
31-34
41-44
Refer to
page
1-66
1-66
1-66