Toshiba e-Studio160 服务手册

下载
页码 239
December 2002 TOSHIBA TEC
1 - 79
e-STUDIO160/200/250 ADJUSTMENT ITEMS
1.8.4  Installing carriage 2
(a) Wire tension adjustment
1. Install wire on carriage 2 by winding up as
shown below.
Fig. 1-8-15
2. Remove the clip jig mounted on scanner drive
shaft.
3. Place the spring jig (wire) tension gauge on wire
holder and scanner drive shaft and then screw
it.
Fig. 1-8-16
4. Remove the spring jig (wire) gauge and loosen
2 screws retaining slide plate.
Fig. 1-8-17
5. To take up the winding slack of wire, move car-
riage 2 back and forth once (to the center of
scanner) and securely hold the carriage to the
left side frame.
6. Tighten 2 screws to secure slide plate.
Fig. 1-8-18
Wire
Wire
Scanner drive shaft
Wire
Wire holder
Scanner
drive shaft
Spring jig (Wire)
Screw
Screw
Carriage 2
Slide plate
Screw
Slide plate
061
062-1
062-2
062-3