Philips P-5794-B 产品宣传页

下载
页码 2
Philips T8 32W Extra Long Life Lamps featuring ALTO II
Technology
Ordering, Electrical and Technical Data
Color
Nom.
Rated Average Life (hrs)
1
Approx.
Product
Ordering
Pack.
Temp.
Length
12-hr on
12-hr on
Initial
Design
Lumen
Number
Code
Watts
Qty.
(Kelvin)
(In.)
Ins. Start
Prog. Start
Lumens
2
Lumens
3
CRI
Maint.
15202-5
F32T8/TL830/XLL /ALTO
32
25
3000
48
40,000
46,000
2950
2800
85
95%
15203-3
F32T8/TL835/XLL /ALTO
32
25
3500
48
40,000
46,000
2950
2800
85
95%
15204-1
F32T8/TL841/XLL /ALTO
32
25
4100
48
40,000
46,000
2950
2800
85
95%
15205-8
F32T8/TL850/XLL /ALTO
32
25
5000
48
40,000
46,000
2850
2700
85
95%
Specifications are subject to change without notice.
© 2007 Philips Lighting Company. All rights reserved.
Printed in USA 06/07
P-5794-B
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory
conditions.For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a
multiplier applied to the designated lamp lumen output.
3) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard
laboratory conditions.
Lamp meets US Federal Minimum Efficiency Standards.
This lamp is better for the environment because of its reduced mercury content. All Philips ALTO II
lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state
and local regulations.
E
0
10,000
20,000 30,000 40,000 50,000
 
0
10,000
20,000 30,000 40,000 50,000
Rated Average Life in Hours
Rated Average Life in Hours
BASED ON 3 HOURS PER START
4
BASED ON 12 HOURS PER START
1
Instant Start Ballast
Programmed Start Ballast
36,000
40,000
40,000
46,000
Rated Average Life
Philips T8 32W XLL Lamps
100%
98%
96%
94%
92%
90%
100%
98%
96%
94%
92%
90%
Lamp Operating Hours
Lamp Operating Hours
L
ig
h
t
O
u
tp
u
t
(%
)
L
ig
h
t
O
u
tp
u
t
(%
)
0
5,000
10,000
15,000
20,000
25,000 30,000 35,000 40,000 45,000 50,000
95% Lumen Maintenance
Philips T8 32W XLL Lamps
E
E
E
E
4) Average life under specified test conditions with lamps turned off
and restarted no more frequently than once every 3 operating hours.
Lamp life is appreciably longer if lamps are started less frequently.
Footnotes from front page:
* When compared to an industry standard 4' T8 32W lamp with 24,000 hours rated average life (12 hours per start on an instant start ballast), with 2800 lumens and 75 CRI.
Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification.
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.