Chauvet 350 用户手册

下载
页码 26
 
 
 
 
Intimidator™ Spot LED 350 User Manual (Rev. 02) 
Page 17 of 26 
Master/Slave 
Mode 
The Master/Slave mode allows a single Intimidator™ Spot LED 350 unit (the “master”) to 
control  the  actions  of  one  or  more  Intimidator™  Spot  LED  350  units  (the  “slaves”) 
without  the  need  of  a  DMX  controller.  The  master  unit  will  be  set  to  operate  in  either 
Automatic or Sound Active mode, while the slave units will be set to operate in Slave 
Mode. Once set and connected, the slave units will operate in unison with the master 
unit. 
Configure the units as indicated below. 
Slave units: 
1.  Press 
<MODE/ESC> repeatedly until SLAv shows on the display. 
2.  Press 
<ENTER> to accept. 
3.  Set the DMX address to 
001
4.  Connect the DMX input of the first slave unit to the DMX output of the master unit. 
5.  Connect the DMX input of the subsequent slave units to the DMX output of the 
previous slave unit. 
6.  Finish setting and connecting all the slave units. 
Master unit: 
1.  Set the master unit to operate in either Automatic or Sound mode. 
2.  Make the master unit the first unit in the DMX daisy chain. 
 
 
 
 
Configure  all  the  slave  units  before  connecting  the  master  unit  to  the  DMX 
daisy chain. 
 
Never connect a DMX controller to a DMX string configured for Master/Slave 
operation  because  the  controller  may  interfere  with  the  signals  from  the 
master unit. 
 
Do not connect more than 31 slave units to the master unit.