Banner American Products R150-3M 产品宣传页

下载
页码 2
LED..I150-3.. Low-Angle LED Ring Lights (150 mm)
Non-Diffused Lighting for Increased Close-Up Contrast
Printed in USA 
 
 
 
 
 
11/06 
 
P/N  127582 rev. A
Features
•   150 mm LED ring light for low-angle illumination. See Banner’s website at  
www.bannerengineering.com
 for a complete lighting tutorial.
•   Uses 3 tiers of LEDs mounted at 75° to the optical axis.
•   Low-angle light enhances contrast of surface defects, etching, and embossed marks.
•  Well suited for dot-peened or pin-stamped data matrix marks.
•  Solid-state LED light source.
•  Continuous or strobed operation is selectable via sensor software.
•  Black anodized aluminum housing with ¼ - 20 threaded mounting holes.
•   The suggested field of view is 80 mm in diameter and the suggested stand off 
is 12.5 mm.
Models
Models*
Illumination
Color
Cable/Connector
Supply Voltage  
and Current
LEDRI150-3W
High-intensity, 
low-angle light
Visible Red 
640 nm
3-conductor, 2 m (6.5') 
attached cable with flying 
leads (see wiring table)
24V dc ±10% @ 500 mA max.
LEDII150-3W
Infrared 
880 nm
24V dc ±10% @ 350 mA max.
LEDRI150-3M
Visible Red 
640 nm
2 m (6.5') pigtail with 
3-pin, 8 mm male 
Pico-style connector 
(direct connection to 
PresencePLUS P4)
24V dc ±10% @ 500 mA max.
Voltage supplied by PresencePLUS sensor,  
if operating at 24V dc (see sensor manual).
LEDII150-3M
Infrared 
880 nm
24V dc ±10% @ 350 mA max.
Voltage supplied by PresencePLUS sensor,  
if operating at 24V dc (see sensor manual).
*For 9 m (30') cable, add suffix “W30” to the model number (e.g., LEDRI150-3W W30).
Specifications
Useful Life
When operated within specification, output will decrease less than 20% after 20,000 hours and less than 30% 
after 30,000 hours.
NOTE: Actual useful life of strobed lights depends on duty cycle.
Environmental Rating
IEC IP0; NEMA 0
Operating Conditions
Temperature: 0° to +50° C (+32° to 122° F) 
Maximum relative humidity: 90% at 50° C (non-condensing) max.
Cleaning Instructions
Regularly remove any dust and dirt from the light source. Blow off dust using anti-static compressed air.
Certifications