Timer Board Diagnostic Testing
 
Press and release the scrub/Ext Wash switch if equipped 
  
If the green indicator light for the scrub switch flashes, the 
scrub/ext wash switch works
START
SCRUB
POWER
PR
4
      
   before testing, turn the power switch OFF and allow the machine to complete the       
 
 drain cycle. 
 
 check incoming voltages
1
        
Open the door 
         
          If the green cycle indicator light blinks, the dOOr sWItch and cyclE lIght work
 
 Note: this function times out after 10 seconds
          close the door 
2
indicator light
POWER
SC
PRIME
START
        
Press and release the start sWItch   
    
          If the green cycle indicator light flashes the start switch works
 
3
indicator light
If one or more components do not run, see below  
POWER
SC
PRIME
START
PrEss start
3 tImEs
 5
fill valve  
detergent pump
rinse-aid pump
•                   
drain valve opens
drain valve closes
wash pump
drain pump or sanitizer pump (if applicable)
to test the timer board and the following components, press 
and release the start switch 3 times with the door closed
     
If the components listed below are operating properly, they
should run consecutively for a few seconds each 
cONdItION
POssIblE causE/sOlutION
One of the components in step 5 does not run
check the component that did not run
the wash pump is the only component that runs
check the 4 amp fuse on the timer board
the wash pump is the only component that will     
  not run and the 4 amp fuse is good
 check pump motor/see troubleshooting guide
 None of the components run in step 5
 check neutral wire/see troubleshooting guide
diagnostic testing for p/n 0712105 solid state timer board
 
 
 
 
- effective serial # W081217467 and up