k) Conveyor Overload or Table Limit Error 2 (L2)
• If the unit shuts down with "L1" in the display and restarts in 3 seconds after the cause of 
the overload is removed, and the inverter sends another overload signal within 3 seconds 
after the conveyor moves, the unit completely shuts down, "L2" appears in the display, and 
the buzzer sounds.
• To reset, use the "ON/OFF" button to turn the unit off and then back on.
  If the unit shuts down with a conveyor overload error, the error signal from the inverter is 
reset, and the unit restarts after 3 seconds. If the cause of the overload (e.g. dish caught in 
conveyor) has not been removed by then, the unit starts and stops repeatedly. To prevent 
this repetition, if the same error occurs within 3 seconds, the unit remains shut down.
  If the unit shuts down with the table limit switch closed, the unit restarts after one or more racks 
are removed, and the table limit switch does not normally close again within 3 seconds. 
• See the chart below for possible causes and remedies.

Conveyor 
Jammed.
Remove obstacle. 
Gear Motor 
Defective. 
Repair or replace. 
Inverter 
Defective. 
Repair or replace. 
Table Limit Switch 
Improper operation. 
Instruct operator. 
Defective. 
Repair or replace. 
Defective (not moving 
smoothly).
Repair. 
Inverter sends another conveyor overload signal 
or table limit switch closes again within 3 
seconds after “L1” error resets and unit restarts. 
L 2 
Code Error 
Item Possible 
Cause 
Remedy 
Unit stops. 
Operation