Rayburn 200SFW 用户手册

下载
页码 8
After completing the installation, the Heating Contractor
should demonstrate to the user, the operation of the
appliance and the routine flue operating method.
1.
Check that the system is full of water and free 
from air pockets. (Rayburn Cookmaster Plus 
212SFW only).
2.
Select and install the appropriate burning grate 
as required by the customer (see Users 
Instructions for method).
3.
When lighting pull the flue chamber damper open 
to maximum.
4.
Add paper and sticks with a small quantity of fuel 
through the fuelling aperture onto bottomgrate 
and close the firebox door.
5.
Open ashpit door, ignite fuel and close ashpit door
when fuel is well alight with spinwheel on ashpit 
door at required setting.
(6.
Allow the cooker to heat up gradually at first time 
lighting.
NOTE: The water capacity of the boiler is 7 litres.
The firebricks fitted to Rayburn Cookers are of first
quality manufacture, and providing the cooker has been
installed and used correctly will have a reasonable life.
They are, however, expendable items and in time will
require renewal.
The renewal of firebricks is not a major operation and
can be carried out by the average person.
Replacement bricks either in sets or singly can be
obtained from your Rayburn distributor.
7
TESTING AND COMMISSIONING
FIREBRICK REPLACEMENT