Patton electronic 2120 用户手册
21
• Connection Retry Frequency: 0 (seconds)
• Local Port: 404
• Remote IP Address: 1.1.1.8
• Remote Port: 23
• Remote Password: UNDEFINED (no entry)
• Remote User ID: UNDEFINED (no entry)
• Session Termination Character: 0x04 (Control-D)
System Defaults
• Boot Message Display Enable: yes
• Default Gateway IP Address: 0.0.0.0 (disabled)
• Unit DHCP Enable: yes
• Unit IP Address: 5.5.5.5
• Unit MAC Address: (Factory Assigned MAC/NIC Address)
• Management Enable: yes
• Management Inactive Timeout: 15 (minutes)
• Prompt: TS>
• Unit Subnet Mask: 255.255.255.0
User Database Defaults
• user database empty!
Note
To reset the Model 2120 software to factory default settings, set
internal dip switch #1 to the ON position and power cycle the
Model 2120 unit. Once powered on, set switch #1 back to the
OFF position. This will reset all settings, with the exception of the
unit MAC address, to the above listed factory defaults.
Model 2120 unit. Once powered on, set switch #1 back to the
OFF position. This will reset all settings, with the exception of the
unit MAC address, to the above listed factory defaults.
3.4 INITIAL UNIT CONFIGURATION
Unless pre-configured with an IP address for your LAN (not standard),
the Model 2120 must be initially configured via the serial interface using
the menu-driven command system and required terminal equipment as
described below:
the Model 2120 must be initially configured via the serial interface using
the menu-driven command system and required terminal equipment as
described below: