Specification Revised 4/09
220244
PT925DN 
GE Profile
 30" Built-In Single/Double Convection Wall Oven
 
KW Rating
240V
3.9
208V 2.9
Breaker Size
240V
20 Amps
208V 20 Amps
Dimensions and Installation Information (in inches)
Most 30” Wall Cabinets can be used with this unit.
Note:
 These ovens are not approved for 
stackable installations. Cabinets installed 
adjacent to wall ovens must have an adhesion 
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets 
and drawers on adjacent 45° and 90° walls should 
be placed to avoid interference with the handle.
Electric wall ovens are not approved for 
installation with a plug and receptacle. They 
must be hard wired in accordance with  
installation instructions
Installation Information: Before installing, consult 
installation instructions packed with product for 
 current dimensional data.
Side-by-side installations require at least 2" 
between cutouts.
CUTOUT
HEIGHT
27 1/4" MIN.
27 5/16" MAX.
CUTOUT
WIDTH
28 1/2" MIN.
28 5/8" MAX.
5"
22" TO
BOTTOM OF 
JUNCTION BOX
JUNCTION B
LOCATION
RECOMMENDED
CUTOUT
LOCATION
32 1/2"
FROM THE 
FLOOR
CABINET
WIDTH
30"
ALLOW 11/16" FOR
OVERLAP OF THE 
OVEN OVER SIDE
EDGES OF CUTOUT
THE OPENING 
BETWEEN INSIDE
 WALLS MUST
BE AT LEAST 
28 1/2"WIDE
ALLOW 1" FOR 
OVERLAP
ON OVEN TOP 
AND BOTTOM 
OF CUTOUT
21"
ALLOW A MINIMUM
F 21" FOR CLEARANCE 
ADJACENT CORNERS, 
RAWERS, WALLS ETC. 
N THE DOOR IS OPENED.
Allow 11/16 
(1.75 cm)  for 
overlap of oven 
over side edges 
of cutout
Cutout
Width
28 1/2” 
(72.4 cm)
Min.
28 5/8” 
(72.7 cm)
Max.
15
(38.1 cm) 
Cabinet
Width
30
(76.2 cm) 
Allow a minimum 
of 15” (38.1 cm) for 
clearance to adjacent 
corners, drawers, 
walls, etc. when 
door is open
Allow 1” (2.5 cm) 
minimum for 
overlap of oven 
top and 1 1/4” 
(3.2 cm) overlap 
of oven bottom 
of cutout
Recommended 
cutout 
location from 
floor 26 1/2” 
(67.3 cm) max
Opening 
Between 
Inside Walls 
Must Be 
At Least 
28 1/2” 
(72.4 cm) 
Wide
Junction Box 
Location
(junction box 
may be 
located in 
adjacent 
cabinet)
9 1/2” 
(12.7 cm)
Max.
Cutout
Height
27 1/4 
(69.2 cm) Min. 
27 5/16 
(69.4 cm) Max.
22 (55.9 cm) 
Min. to
Bottom of 
Junction Box
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
(must support 275 lbs.)
Cutout width
28-1/2'' MIN.
28-5/8'' MAX.
29-3/4
C
30
Recommended 
cutout location 
32-1/2" 
from floor
21
Junction 
box
location
Allow minimum of 21'' for clearance
to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.
C=28-1/4" without trim and 28-3/4" with trim.
Conduit
(72" 
long)
5
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
A
B
23-1/2'' MIN.
Cutout depth
22'' MIN.