FULL SIZE GAS CONVECTION OVENS - CONDENSED SPARE PARTS LIST
CODE & PROBLEM
PROBABLE CAUSE
SOLUTION
F32700 (February 2006)
Printed in U.S.A.
Er06 - Zone 1 A/D underflow
error
• Incorrect sensor type
• Measuring temperature outside the
sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections  for a
reversed or open sensor. If  the
condition causing the error is 
resolved, the error will clear.
Er07 - Zone 1 A/D overflow
error
Open sensor
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections  for a
reversed or open sensor. If  the
condition causing the error is 
resolved, the error will clear.
Er10 - Stack overflow error
Microprocessor malfunction
• Cycle power.
• Check sensor and connections  for a
reversed or open sensor.
Er11 - Open sensor error
Open sensor
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections  for a
reversed or open sensor.
Er12 - Shorted sensor
• Incorrect sensor type
• Measuring temperature outside  the
sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections  for a
reversed or open sensor.
CONDENSED SPARE PARTS LIST
WKG SERIES
Part No.
Description
340324-8
Main Power Switch (On/Off/Oven Cool)
411506-3
Thermostat, KX (WKG, WKGX)
353613-2
Temperature Control Board (WKGD, WKGDX)
353589-1
Temperature Probe (WKGD, WKGDX)
411496-F1
Door Switch
497269-1
Gas Valve, Natural
497269-2
Gas Valve, Propane
427137-2
Ignition Module
416535-6
Heat Relay
346357-1
High Limit Thermostat
424194-1
Igniter/Flame Sensor
411690-1
Timer - 60 Minute
340324-9
Light Switch, Roast & Hold or Fan Speed
358516-1
Blower Motor, 2Sp. 120 Volt
424846-1
Computer Control (WKGC, WKGCX)
920883-3
Temperature Probe (WKGC, WKGCX)
821875-2
SST Relay (WKGD, WKGDX)
421758-G1
Transformer