Impinger I -–1000 Series Service Manual - International 
11 
TIME/TEMP 
DISPLAY(S/N Q14790 & 
Below, 1200 series S/N 
Q14973 & Below, 1000 
series)  
 
(S/N Q14791 & Above, 
1200 series S/N Q14974 
& Above,  
1000 series refer to Pg. 
9) 
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 
VAC to the primary of the12.6 volt Transformer. The secondary output of the 
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is 
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is 
terminal 2. The display works on a balanced input and center tap voltage to each leg 
must be 1/2 the total reading. 
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach. 
coupling) to break the infra-red light beam of the optical switch (mounted on gear 
motor) producing electrical pulses that are transmitted to the display. The display 
converts these pulses into a read-out of minutes and seconds. The temperature 
portion of the display uses a Thermistor Probe to sense oven temperature. The 
thermistor outputs a resistance proportional to the oven temperature. This resistance 
is then converted by the display into a temperature reading.