Lincoln 1600-000-A 用户手册

下载
页码 24
Low Profile – 1600 Series Advantage Digital Service Manual – Domestic 
TROUBLESHOOTING GUIDE 
GAS OVENS 
 
MODEL 1600-000-A 
NATURAL GAS 
120 VAC. 
60 HZ. 
1 PHASE 
MODEL 1601-000-A 
LP GAS 
 
120 VAC. 
60 HZ. 
1 PHASE 
 
 
NOTE: When checking components on left side of oven, be sure to check for proper connections  in power 
connector, (marked P.C. on schematic diagram) located inside motor cover. 
 
SYMPTOM 
POSSIBLE CAUSE 
EVALUATION 
Oven fan will not run 
Incoming power    
supply 
Check circuit breakers, reset if required. Check power plug to be 
sure it is firmly in receptacle. Measure the incoming voltage. Call 
power co. if needed. 
 
Power switch 
Check continuity between switch terminals. Replace switch as 
needed. 
 
Fuse, 10 Amp 
Check, replace if necessary. 
 
Fuse holder 
Check, replace if necessary. 
 
Fuse, 3 Amp 
Check, replace if necessary. 
 
Fuse holder 
Check, replace if necessary. 
 
Hi-limit thermostat(s), 
control box 
Check for voltage on both sides of the switch. Terminals are 
normally closed. If open, reset and test oven for proper operation. 
If thermostat will not hold, and control box temperature is not 
exceeding 140
°F (60°C), replace thermostat 
 
Relay, oven power 
Check for 120 VAC to the relay coil. If voltage is not present, 
Trace wiring back to the hi-limit thermostat. If voltage is present, 
check to insure contacts are closing. Check for 120 VAC supplied 
to terminal #2 of the relay. If voltage is not present at terminal #2, 
trace wiring back to the 10 Amp fuse. Replace relay as needed. 
 
Motor, main fan 
Check for opens, shorts or grounds. WITH POWER OFF: turn 
fan blade to check for locked rotor. 
 
Capacitor 
Check for shorts or grounds. WARNING: Capacitor has a stored 
charge, discharge before testing. 
No control box cooling 
Incoming power 
Check circuit breakers, reset if required. Check power plug to be 
sure it is firmly in receptacle. Call power co. if needed. 
 
Power switch 
Check continuity between switch terminals. Replace switch as 
needed. 
 
Fuse, 3 Amp 
Check, replace if necessary. 
 
Fuse holder 
Check, replace if necessary. 
 
Hi-limit thermostat(s), 
control box 
Check for voltage on both sides of the switch. Terminals are 
normally closed. If open, reset and test oven for proper 
operation. If thermostat will not hold and control box temperature 
is not exceeding 140
°F (60°C), replace thermostat. 
 
Cooling fan(s) 
120 VAC should now be at the fan motor. If voltage is not 
present, trace wiring back to hi-limit thermostat. Check motor for 
opens, shorts or grounds. WITH POWER OFF: Check for locked 
rotor.  
No automatic control box 
cooling 
Incoming power 
supply 
Check circuit breakers, reset if required. Check power plug to be 
sure it is firmly in receptacle. Call power co. if required. 
 
Cooling fan 
thermostat(s) 
Check the cooling fan thermostat. (thermostat closes at 120
°F 
and opens at 100
°F) With the cooling fan thermostat preheated, 
check for continuity. If switch is open, replace thermostat. 
 
Fuse, 3 Amp 
Check, replace if necessary. 
 
Fuse holder 
Check, replace if necessary. 
 
Hi-limit thermostat(s) 
control box 
Check for voltage on both sides of switch. Terminals are 
normally closed. If open, reset and test oven for proper 
operation. If thermostat will not hold, and control box