Whirlpool MAH9700AW 用户手册
©2005 Maytag Services
16025909 Rev. 0
27
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
death; disconnect power to unit before servicing.
Disassembly Procedures
WARNING
!
Reactor Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove single attachment screw on cross brace.
4. Twist Reactor counterclockwise to remove.
2. Remove Top Cover.
3. Remove single attachment screw on cross brace.
4. Twist Reactor counterclockwise to remove.
NOTE: The reactor coil is wired in series with line 1
internally in the Control Board. An open coil or
loose electrical connection would result in a
“dead” board complaint. A resistance check
across the coil leads should indicate less than 1
ohm.
loose electrical connection would result in a
“dead” board complaint. A resistance check
across the coil leads should indicate less than 1
ohm.
EMI Filter Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Loosen 13mm acorn nut and slide EMI Filter out of
2. Remove Top Cover.
3. Loosen 13mm acorn nut and slide EMI Filter out of
bracket.
NOTE: Mark the wire locations on the EMI before
removing the terminals.