Bunn JDF-4D 用户手册

下载
页码 57
24
SERVICE (CONT.)
Condenser Fan (all Models)
P1684.40
FIG. 21 CONDENSER FAN
Location:
The condenser fan is located inside the main frame 
below the compressor assembly.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the 2-pin from the fan to the main wiring 
harness.
3.  Check for continuity across the fan terminals.
If continuity is present as described, reconnect the 
wires to the fan terminals.
If continuity is not present as described, replace the 
fan.
Removal and Replacement:
1.  Disconnect the dispenser from the power source.
2.  Remove the four screws attaching the fan and cover 
assembly to the refrigeration cabinet.
3.  Gently pull the cover assembly forward and discon-
nect the 2-pin connector from the fan to the main 
harness.
4.  Remove the fan from the cover assembly and dis-
card.
5.  Install the new fan onto the cover assembly.
6.  Reconnect the wiring harness to the new fan.
7.  Install fan and cover assembly using four screws 
previously removed.
8.  Reconnect power to the dispenser.
FIG. 22 CONDENSER FAN TERMINALS
P1219
JDF-4S shown
BLU/BLK
WHI
49179  110613