Cecilware JAVA2-LP 用户手册

下载
页码 12
 
PROGRAMMING
 INSTRUCTIONS FOR AUTOMATIC DISPENSE   
1.  Turn Power Switch ON (toggle switch inside door).  
2.  PRESS and HOLD [red] STOP Button with one hand.  
3.  PRESS and HOLD [green] DISPENSE Button with other hand.   
4.  RELEASE [red] STOP Button ONLY.  
5.  Continue to HOLD [green] DISPENSE Button for 5 SECONDS, then RELEASE.   
6.  PRESS and RELEASE [green] DISPENSE Button. Product begins dispensing.    
     When it reaches the "DESIRED VOLUME",   
7.  PRESS and RELEASE [green] DISPENSE Button to SET "DESIRED VOLUME".    
     DISPENSE Button can be "jogged" to top off.  
8.  PRESS and RELEASE [red] STOP button to LOCK IN "DESIRED VOLUME".  
     Repeat steps 1 to 8 for each Dispense Button.  
 
PROGRAMMING INSTRUCTIONS FOR MANUAL DISPENSE  
1.  PRESS AND HOLD STOP [red] BUTTON WITH ONE HAND.  
2.  PRESS AND HOLD DISPENSE [green] BUTTON WITH OTHER HAND.  
3.  RELEASE STOP [red] BUTTON.  
4.  RELEASE DISPENSE [green] BUTTON.  
5.  PRESS AND RELEASE STOP [red] BUTTON. 
 
The Total Time The Water Is Running Is Accumulated  And Saved Into Memory.  For Normal Operation,  
Press and Release Dispense Button.   
 
The Automatic Dispense Buttons are factory programmed to dispense 8 oz. of Water per cup. 
 
PRODUCT STRENGTH ADJUSTMENTS: 
 
The JAVA units have variable speed control auger motors [CD151 with variable 
speed of 10 to 130 RPM].   
Drink or Product Strength can be changed by adjusting the Gram Throw Dial on inside door panel. 
The Gram Throw is factory preset at approx. 2.4 (2.2 gr. per 8 oz. cup) for the JAVA2-LP machines. 
The water flow rate adjustment for the dispense valve should remain fixed bet. 1 - 1.3.   
 
 
HOT WATER FLOW RATE ADJUSTMENTS:    
 
Note:  Remove right side panel to access the Water Dispense Valves, . 
 
TO ADJUST HOT WATER FLOW RATE: 
1.  Remove right side panel to access the Water Dispense Valves, mounted on tank. 
2.  Locate adjustment screw on Dispense Valve. 
3.  Using Allen Key or flat screwdriver rotate, 1/4 turn at a time,  
     CLOCKWISE  to decrease water flow, or COUNTERCLOCKWISE to increase water flow. 
4.  Check water flow output, after each 1/4 turn. 
 
 
 
 
 
3