Cecilware BC302 用户手册

下载
页码 18
 
4
INITIAL PRIMING
 – Filling of Tank 
 
The BC Brewers are shipped with the Thermostat in the OFF position.  Do not turn Thermostat to the ON 
position until the Brewer has been fully primed. 
a.  Turn water supply on and check for leaks at the water inlet connections.  Tighten compression fitting if 
necessary. 
 
b.  Turn on power to the Brewer.  The Brewer will automatically start filling.  After 6 minutes the filling cycle will 
stop and the thermostat should be turned clockwise to the full ON position.  Allow approximately 20 minutes for 
the brewer to reach full brewing temperature (197'-203').   
When the GREEN READY LIGHT comes ON the brewer is ready to brew the next batch of coffee. 
 
NOTE:
  Before proceeding further, make sure the sample Filter pack has been removed from the 
funnel. 
 
CHECKING BREW CYCLE OUTPUTS. 
The BC-Series brewers are factory preset to deliver the proper amount of brewing water for the 12 cup, 
24 cup and 36 cup brew cycles.  Nevertheless, it is a good practice to check the output levels prior to 
brewing the first batch of coffee. 
 
BC1 and BC2: Full 36 cups (3 decanters) per brew cycle with a 20% by-pass. 
BC120 and BC240: Selectively 12 cups (1 decanter) or 24 cups (2 decanters) per brew cycle. 
No by-Pass.  
BC301 and BC302: Selectively 12, 24 and 36 cups per brew cycle with a 20% by-pass for the 36 cup 
cycle only. 
 
TO START A BREW CYCLE: 
Turn Warmer Switch to the ON position.  The Warmer Switches also double as CYCLE STOP switches.  
With Funnel and Carrier in place activate GREEN BREW switch. 
 
On BC120, BC240, BC301 and BC302 brewers first activate brew switches marked 12 cups and then 
check output.  Do the same with the 24 cup brew switch and the 36 cup brew switch for the BC301 and 
BC302 units. 
 
NOTE:  12 cups equal 1 full decanter.  
 
If necessary adjust the timer(s) to increase or decrease output levels.  See Timer adjustments. 
 
COFFEE BREWING INSTRUCTIONS 
 
Place filter paper into brew basket and add finely ground coffee as per chart below: 
 
MODEL# 
CUPS  BREWED 
RECOMMENDED COFFEE 
AMOUNT 
TOTAL BREW TIME 
Single 
BC120 
12 / 24 Cups 
2 oz./ 4 oz.
3.0 / 4.5 Minutes 
Single 
BC240 
12 / 24 Cups 
2 oz./ 4 oz.
3.0 / 4.5 Minutes 
Single 
BC1 
36 Cups 
6 oz.
6.0 Minutes 
Twin 
BC2 
2 x 36 Cups 
2 x 6 oz.
6.0 Minutes 
Single 
BC301 
12 / 24 / 36 Cups 
2 oz./ 4 oz./ 6 oz.
3.0 / 4.5 / 6.0 Minutes 
Twin 
BC302 
2 x (12 / 24 / 36 Cups) 
2x  (2 oz./ 4 oz./ 6 oz.)
2x (3.0 / 4.5 / 6.0 Minutes)
 
Insert brew funnel back into brewer and position empty carriers under brew funnels.  With Warmer 
Switches 
on (lit), depress Green Brew Switches.  Total brew time will vary according to cups selected.  
After funnel stops dripping, remove and empty funnels. 
 
Warning: Remove Brew funnel ONLY after it has stopped dripping.