INSTALLATION AND OPERATING INSTRUCTIONS 
 
Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the  
data label of the Brewer. 
 
UNPACKING AND INSPECTION 
Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer. 
 
 
ASSEMBLY AND SET-UP 
The Brewer is shipped complete with: 
DESCRIPTION 
BC1, 301,  120, 240 
BC2, 302 
Adjustable legs 
Carriers complete with Faucets and Covers  
Funnels with sample Filter pack     
 
 
Remove carriers from Brewer, one has the four (4) legs packed inside.  Install legs by tilting Brewer on its 
back and screwing the legs into the threaded leg supports on bottom. 
 
WATER HOOK UP 
The National Sanitation Foundation (NSF) requires the following for NSF approved installation: 
1.  A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so 
that the Brewer can be moved for cleaning underneath. 
2.  An approved flow-back prevention device such as a double check valve to be installed between Brewer 
and water supply. 
 
WATER CONNECTION 
The Brewer comes equipped with a ¼ inch compression water inlet fitting located in the back. Use a ¼ inch 
copper tubing to connect the Brewer to a cold water supply. Water pressure should be:  20 PSI min. to 90 
PSI max. An external shut-off valve and a water filtering system with a charcoal filter are highly 
recommended.   
 
Turn water supply on and check for leaks at the water inlet connections, tighten compression fitting if 
necessary. 
 
ELECTRICAL CONNECTIONS 
A terminal block inside the base compartment is provided for electrical connections. Opening for field 
conduit connections are provided in the bottom and the back of the base. 
To access the Terminal Block, loosen the 2 screws on the side of the base cover. Disengage base cover 
from rear panel by lifting base cover up and lifting back towards rear panel. 
 
Power Cord CE202 – Optional  ?
 
 
RECOMMENDED WIRING SIZES 
Model No. 
                              
 
Single (1) Phase 
Single:  BC1, BC301, BC120, BC240 
 
    12 AWG 
Twin:   BC2, BC302 
                            10 AWG 
 
Note: 
1.  Neutral (N) and Ground Wires to be 14 AWG Minimum. 
2.  Field wiring must be suitable for 75º C. 
3.   Use Copper wire only for all power supply connections.