Traulsen RCV232WUT-FHS 产品宣传页

下载
页码 2
Project
Quantity
Item #
Model Specified:
CSI Section 11400
TRAULSEN
4401 BLUE MOUND RD.
FT. WORTH, TX 76106
PHONE 1 (800) 825-8220
FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
SECTION
7-8
Construction, Hardware and Insulation
Cabinet exterior, including front, one piece sides, louver assembly and doors are
constructed of heavy gauge stainless steel. Cabinet interior and door liners are
constructed of stainless steel (anodized aluminum in the A-Series). Exterior cabinet
top, back and bottom are constructed of heavy gauge aluminized steel.  Adjustable
6" high stainless steel legs are included.
Doors are equipped with removable plug cylinder locks and guaranteed for life
cam-lift, gravity action, self-closing metal, glide hinges with stay open feature at 120
degrees. Hinges include a switch to automatically activate the interior incandescent
lighting. Guaranteed for life, work flow door handle is mounted horizontally over
recess in door which limits protrusion from door face into aisleways.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Cabinet and door contains high density, non-CFC, foamed in place polyurethane
insulation.
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any
additional warranties. For fast order entry: Fax 1 (800) 765-8728.
Continued product development may necessitate specification changes without notice.
Part No. TR35815 (created 1/07)
Specifications
Refrigeration System
A top mounted, self-contained, balanced refrigeration system using R-404A refriger-
ant is conveniently located behind the one piece louver assembly. It features a ple-
num effect blower coil, large, high humidity evaporator coil located outside the food
zone, top mounted non-electric condensate evaporator, and an automatic
preset time activated electric defrost.  A face mounted key switch is provided to
convert operation from freezer to refrigerator mode.  Standard operating tempera-
ture in freezer mode is 0 to -5°F.  Operating temperature in refrigerator mode is 34 to
38°F.  Operating temperatures are not adjustable.
Controller
The water resistant digital microprocessor control is provided.  It includes an 3-digit
LED temperature display in addition to features such as a defrost lock-outs and
indicator light.
Interior
Standard interior arrangements include three (3) chrome plated wire shelves per
section, mounted on shelf pins. Shelves are full-width, and do not have any large
gaps between them requiring the use of "bridge" or "junior shelves."  Recommended
load limit per shelf should not exceed 225 lbs. Optional tray slides may be
purchased in combination with, or in lieu of these.  Both standard and optional
interior arrangements are completely installed at the factory.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self-
contained models only) are provided standard.  An optional 2
nd
 year extended parts
and labor warranty is also available. In addition the microprocessor control is
warranted by a two year parts and labor warranty.
Equipped With One NEMA 5-15P Plug
(1 Section Models Only)
Equipped With One NEMA 5-20P Plug
(2 Section Models Only)
NOTES
NOTE: Figures in parentheses reflect metric equivalents.
1=Wattage is determined by listed amps X listed volts X an average run time of 70%
for refrigerators and 80% for freezers.
2=Based on a 90 degree F ambient and -10 degree F evaporator.
3=For approximate remote weights deduct 40 lbs. from respective net or gross weight.
For other information on remote models, please refer to spec sheet 12-2.
DIMENSIONAL DATA
R/ACV132WUT
R/ACV232WUT
Net capacity cu. ft.
24.2 (686 cu l)
51.6 (1462 cu l)
Length - overall in.
29
7
8
 (75.9 cm)
58 (147.3 cm)
Depth - overall in.
35 (88.8 cm)
35 (88.8 cm)
Depth - over body in.
32 (81.3 cm)
32 (81.3 cm)
Depth - with door open
57
11
16
 (146.5 cm) 57
11
16
(146.5 cm)
90 degrees in.
Clear door width in.
21
1
8
 (53.6 cm)
21
1
8
 (53.6 cm)
Clear half-door height in.
27
1
2
 (69.9 cm)
27
1
2
 (69.9 cm)
Clear full-door height in.
57
5
8
 (146.3 cm)
57
5
8
 (146.3 cm)
Height - overall on 6" legs
83
1
4
 (211.5 cm)
83
1
4
 (211.5 cm)
Shelf area sq. ft.
18.8 (1.75 sq m) 37.6 (3.49 sq m)
RCV Net Wt. lbs.
415 (188 kg)
705 (320 kg)
ACV Net Wt. lbs.
365 (166 kg)
625 (283 kg)
ELECTRICAL DATA
Voltage
115/60/1
115/60/1
Feed wires with Ground
3
3
Full load amperes
11.5
14.9
Wattage
1
1058
1371
REFRIGERATION DATA
Refrigerant
R-404A
R-404A
BTU/HR H.P.
2
2160 (
1
2
 HP)
3790 (
3
4
 HP)
Plan - R/ACV132WUT
Elevation -
R/ACV132WUT
Section - All Models
Plan - R/ACV232WUT
Elevation -
R/ACV232WUT
REQUIRED CLEARANCES
In order to assure optimum performance, the condensing unit MUST have an adequate supply of
air for cooling purposes.  Therefore, the operating location must either have a minimum of 12”
clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit.
Clearance of at least 12” above is required in order to perform certain maintenance tasks.