Delfield F18BC 用户手册

下载
页码 22
F18 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
4
Delfield
®
Specifications
MODEL 
# OF 
 
SHELF AREA 
# OF 
RECOMMENDED 
VOLTS/HERTZ/ 
  
BTU DESIGN 
EVAP. CAP. 
NUMBER 
DOORS 
 
SQ. FT. 
PANS 
HORSE POWER 
PHASE 
AMPS 
BASE/RAIL 
BTU/°TD 
Remote Refrigerated Salad Top Tables
F18SR31A
 
(1) 19” 
 
2.56 
1/4 
115/60/1 
3.0 
280/265 
120
F18SR44A 
(2) 19” 
 
5.12 
1/4 
115/60/1 
3.0 
491/441 
120
F18SR44B 
(2) 19” 
 
5.12 
1/4 
115/60/1 
3.0 
491/441 
120
F18SR44C 
(2) 19” 
 
5.12 
10 
1/4 
115/60/1 
3.0 
491/441 
120
F18SR52A 
(1) 19” & (1) 27” 
 
6.51 
1/4 
115/60/1 
3.0 
532/529 
120
F18SR52B 
(1) 19” & (1) 27” 
 
6.51 
1/4 
115/60/1 
3.0 
532/529 
120
F18SR52C 
(1) 19” & (1) 27” 
 
6.51 
10 
1/4 
115/60/1 
3.0 
532/529 
120
F18SR52D 
(1) 19” & (1) 27” 
 
6.51 
12 
1/4 
115/60/1 
3.0 
532/529 
120
MODEL 
# OF 
 
SHELF AREA 
# OF 
  
VOLTS/HERTZ/ 
  
BTU DESIGN 
BTU SYSTEM CAP.
NUMBER 
DOORS 
 
SQ. FT. 
PANS 
HORSE POWER 
PHASE 
AMPS 
BASE/RAIL 
BASE/RAIL
Self-Contained Refrigerated Salad Top Tables
F18SC39A
 
(1) 19” 
 
2.56 
1/4 
115/60/1 
10.0 
280/265 
1903/745
F18SC39B 
(1) 19” 
 
2.56 
1/4 
115/60/1 
10.0 
280/353 
1903/867
F18SC52A 
(2) 19” 
 
5.12 
1/4 
115/60/1 
10.0 
444/265 
1903/745
F18SC52B 
(2) 19” 
 
5.12 
1/4 
115/60/1 
10.0 
444/353 
1903/867
F18SC52C 
(2) 19” 
 
5.12 
10 
1/4 
115/60/1 
10.0 
444/441 
1903/971
F18SC52D 
(2) 19” 
 
5.12 
12 
1/4 
115/60/1 
10.0 
444/529 
1903/1061
F18SC60A 
(2) 19” & (1) 27” 
 
6.51 
1/4 
115/60/1 
10.0 
515/265 
2314/667
F18SC60B 
(2) 19” & (1) 27” 
 
6.51 
1/4 
115/60/1 
10.0 
515/353 
2314/798
F18SC60C 
(2) 19” & (1) 27” 
 
6.51 
10 
1/4 
115/60/1 
10.0 
515/441 
2314/916
F18SC60D 
(2) 19” & (1) 27” 
 
6.51 
12 
1/4 
115/60/1 
10.0 
515/529 
2314/1023
A 5-15P NEMA plug is used on self-contained units
MODEL 
# OF 
STORAGE 
SHELF AREA 
# OF 
RECOMMENDED 
VOLTS/HERTZ/ 
  
BTU DESIGN LOAD 
EVAP. CAP. 
NUMBER 
DOORS 
CU. FT. 
SQ. FT. 
PANS 
HORSE POWER 
PHASE 
AMPS 
BASE/RAIL 
BTU/°TD 
Remote Refrigerated Reduced Height Rail
F18DR44
 
(2) 19” 
9.49 
5.12 
10 
1/4 
115/60/1 
3.0 
547/441 
120/19
F18DR52 
(1) 19” & (1) 27” 
11.81 
6.51 
12 
1/3 
115/60/1 
3.0 
625/529 
120/23
F18DR60 
(2) 27” 
14.14 
7.9 
16 
1/3 
115/60/1 
5.0 
703/617 
120/26
F18DR70 
(2) 32” 
17.05 
9.64 
18 
1/2 
115/60/1 
5.0 
800/794 
120/32
F18DR79 
(1) 19” & (2) 27” 
18.68 
10.29 
18 
1/2 
115/60/1 
5.0 
962/882 
240/36
F18DR87 
(3) 27” 
21.30 
11.85 
22 
3/4 
115/60/1 
5.0 
1032/970 
240/39
MODEL 
# OF 
STORAGE 
SHELF AREA 
# OF 
  
VOLTS/HERTZ/ 
  
BTU LOAD 
BTU SYSTEM CAP.
NUMBER 
DOORS 
CU. FT. 
SQ. FT. 
PANS 
HORSE POWER 
PHASE 
AMPS 
BASE/RAIL 
BASE/RAIL
Self-Contained Refrigerated Reduced Height Rail
F18DC52
 
(2) 19” 
9.49 
5.12 
12 
1/4 
115/60/1 
10.0 
547/529 
1903/1061
F18DC60 
(1) 19” & (1) 27” 
11.81 
6.51 
14 
1/3 
115/60/1 
12.0 
625/617 
2314/1121
F18DC68 
(2) 27” 
14.14 
7.9 
18 
1/3 
115/60/1 
12.0 
703/794 
2314/1544
F18DC82 
(2) 32” 
17.05 
9.64 
20 
1/2 
115/60/1 
14.0 
800/882 
3097/1648
F18DC91 
(1) 19” & (2) 27” 
18.68 
10.29 
22 
1/2 
115/60/1 
14.0 
962/1058 
3807/1839
F18DC99 
(3) 27” 
21.30 
11.85 
24 
3/4 
115/60/1 
16.0 
1032/1147 
5286/2191
A 5-15P NEMA plug is used on F18RC52, F18RC60 & F18RC68 . A 5-20P NEMA plug is used on , F18RC82, F18RC91, & F18RC99.