Vulcan-Hart VGL60 产品宣传页

下载
页码 2
P.O. Box 696 
  Louisville, KY 40201 
  Toll-free: 1-800-814-2028 
  Local: 502-778-2791 
  Quote & Order Fax: 1-800-444-0602
 
a division of ITW Food Equipment Group LLC
S T E A M
F-32050 (04/10)
VGL SERIES
GAS STATIONARY 
2
3
 JACKETED KETTLES
NOTE: In line with its policy to continually improve its products, Vulcan reserves the right to change materials and specifications without notice.
MODEL
NO.
BTU/HR.
INPUT
BRIMFUL
CAPACITY*
4 OZ.
SVGS.
A
B
C
D
E
F
G
H
J
K
VGL20
100,000
20 gal., 80 qts.
76 liters
640
20 
508
27
1
2
698
40
1016
32
813
3
76
19
483
64
1626
24
610
30
1
2
775
6
152
VGL40
100,000
40 gal., 160 qts.
152 liters
1280
26
660
32
1
2
825
44
1118
38
1
2
978
2
51
19
483
72
1829
29
737
35
889
6
152
VGL60
130,000
60 gal., 240 qts.
227 liters
1920
30
762
36
1
2
927
49
1
2
1257
42
1016
2
1
2
63
21
1
2
546
85
2159
35
889
39
991
8
203
* Working capacity 70% to 80% of brimful depending on model.
IMPORTANT:
1.  A pressure regulator sized for this unit is included. Minimum 
 supply pressure: Natural gas 7" W.C. Propane 11" W.C.
2.  Gas line connecting to unit must be 
3
4
" or larger. If flexible 
 connectors are used, the inside diameter must be at least the 
same as the 
3
4
" iron pipe and rated for the correct gas input.
3.  Requires 120 volt, 60 Hz, 1 phase electrical connection.  
Furnished with 6' cord and 3 prong plug. 3 amp total draw.
4.  An adequate ventilation system is required for commercial 
 cooking equipment. Information may be obtained by writing to the 
National Fire Protection Association, Batterymarch Park, Quincy, 
MA 02269. When writing, refer to NFPA No. 96.
5.  These units are manufactured for installation in accordance with 
ANSZ223.1a (latest edition), National Fuel Gas Code. Copies may 
be obtained from the American Gas Association. 1515 Wilson 
Blvd., Arlington, VA 22209.
6.  Equipment clearance: 
Combustible 
Non-Combustible
 
Rear 
2" 
2"
 
Right 
6" 
6"
 
Left 
6" 
6"
7.  This appliance is manufactured for commercial installation only 
and is not intended for home use.
GS:  See #1 & #2 above.
EC:  See #3 above.