Problem 
Possible Causes / Suggested Corrective Action 
Will Not Turn On, no power 
light 
Kettle is not plugged in / Plug in power cord. 
Power switch is off / Turn on power switch. 
Circuit Breaker tripped / Reset Breaker 
Ground Fault Receptacle is tripped  / Reset Ground Fault 
Receptacle 
Hood system with power interrupt is not on  / Turn on hood system. 
Tilt kettle not in the fully lower position / Lower kettle with crank to 
the level position 
Note:  If the kettle still does not come ON verify that there is power 
at the receptacle by plugging in another electrical device such 
at a lamp.  If the device does not come ON call an electrician or 
maintenance personel.  If the alternate  device does come ON, call 
your authorized Vulcan Servicer. 
Low Water Light On or Low 
water in Sight Glass 
Water level to low / Fill jacket per instructions in this manual. 
Relief valve is not seated and leaking / With no pressure on gauge, 
lift lever on relief valve and allow it to snap closed, refill jacket per 
instructions in this manual 
Fill port is not fully closed and leaking / Close tightly fill port valve, 
refill jacket per instructions in this manual. 
Jacket was refilled with deionized water / Add a pinch of salt to 
jacket water. 
Not Heating, Ignition Fail 
Light Is On 
Gas Supply Valve is off  / Turn on gas valve 
Combo Valve is off / Turn on combo valve 
Quick connect hose not connected or fully inserted  / Connect quick 
connect hose or push connector in till quick connect snaps and 
locks. 
Gas line, flex hose, or quick connect undersize and not delivering 
enough gas  /  Increase gas line size to 125% of kettel rated BTU 
input. 
Gas supply pressure to low  / Have plumber Increase gas supply 
pressure 
Kettle not in vacuum when 
cold or will not boil when up 
to pressure 
Air in jacket / Vent per instructions in this manual. 
Relief valve is not seated and leaking / With no pressure on gauge, 
lift lever on relief valve and allow it to snap closed, vent jacket per 
instructions in this manual 
Fill port is not fully closed and leaking / Close tightly the fill port 
valve, vent jacket per instructions in this manual. 
Note:  If the kettle jacket continues to loose vacuum or requires 
frequent refilling of the jacket call your authorized Vulcan Servicer.