SERVICE (cont.)
TANK HEATER
Location:
 
The tank heater is located inside the tank and 
secured to the tank lid.
Test Procedures:
1.  Disconnect the brewer from the power supply.
2.  Turn on thermostat. Check the voltage across the 
black and white wires on 120 volt models or the 
black and red wires for 200 volt models and 230 
volt models with a voltmeter. Connect the brewer 
to the power source. The indication must be:
 
a) 120 volts ac for  two  wire 120 volt 20 amp 
models .
 
b) 200 to 230 volts ac for two wire 200 or 230 volt 
models. 
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4
If voltage is not present as described, refer to the Wir-
ing Diagrams and check wiring harness.
4.   Disconnect the wires from the tank heater termi-
nals.
5.   Check resistance value across tank heater terminals 
and compare to chart.
If resistance is present as described, reconnect the 
wires, the tank heater is ok.
FIG. 13-1 TANK HEATER
1680W-120V  
         7.9   -  9.2 
1680W-100V  
         5.5   -6.4 
1680W-230V  
       29.0   -33.7 
TERMINAL TO SHEATH - INFINITE (OPEN)
      HEATER                   RESISTANCE
If resistance is not present as described, replace the 
tank heater.
NOTE-
 If any resistance is read between sheath and 
either  terminal,  remove  and  inspect  heater  for 
cracks in the sheath.
Removal and Replacement:
1.  Disconnect the brewer from the power supply.
2.  Disconnect the water supply from the brewer.
3.  Disconnect the wires from the limit thermostat.
4.   Disconnect the wires from the tank heater termi-
nals.
5.  Remove sprayhead and the  hex nut securing the 
sprayhead tube to the hood. Set aside for reas-
sembly.
6.  Remove the six #10 screws securing the tank lid 
to the tank.
7.   Remove the tank lid with limit thermostat, spray-
head tube and tank heater.
8  Remove the two hex nuts securing the tank heater 
to the tank lid. Remove tank heater with gaskets 
and discard.
9.  Install new tank heater with gaskets on the tank 
lid and secure with two hex nuts.
10. Install tank lid with limit thermostat, sprayhead 
tube and tank heater using six #10 screws.
11. Secure  sprayhead  tube  to  hood  using  hex  nut 
removed in step 4.
12. Install sprayhead.
15. Reconnect the wires to the limit thermostat and 
tank heater.
16. Reconnect the water and power supply.
41722 070209