When this condition exists the oven will sound an audible alarm by 
emitting a triple beep (three quick short beeps) every 2 seconds 
and it will flash the message “Err too Hot” on the display to alert 
nearby staff. The audible alarm may be temporarily canceled FOR 
3 MINUTES by pushing ADJ/SET. After 3 minutes have expired 
the  oven  will  begin  beeping  again.  The  error  message  on  the 
display cannot be canceled. The proper action when this alarm 
is present is to turn the oven off and call for service. 
IV. e - TESTING THE OVEN:
Before using the oven for the first time, verify that the oven oper-
ates normally.
Check that the oven is connected to the correct power source.
Turn the oven ON at the power switch.
Use the controls to set the HOLDING TEMPERATURE to 140
0
F.
Check that the oven circulating fans are running.
Check that the heaters ON indicator is lit.
Check that the oven is warming to the displayed holding tem-
perature.
NOTE:
  The cooling fans may not operate when the oven is first 
turned on.  The cooling fans operate only when the thermostat 
to which they are connected requires it.
Set the TIME to 2 hours, Set the RETHERM TEMP to 250
0
, push 
the START BUTTON, check the interior rear of the oven cavity to 
determine that the oven is heating.
Push the ADJ/SET knob to cancel the cycle, set the TIME to 0, 
set the HOLD TEMP to 250
0
F, push the START BUTTON.
Check that the RETHERM TEMP display has been blanked and 
the HOLD TEMP display is lighted.
Check  the  interior  rear  of  the  oven  to  ensure  that  the  oven  is 
heating.    If    all  the  functions  perform  satisfactory,  the  oven  is 
ready for operation.
 IV. f - OPERATING THE OVEN:
Main Features
Flexibility-Manual  setting  of  the  parameters  RETHERM  TIME, 
HOLD TEMP and RETHERM TEMP.
Quick  cycle  start-Press  START  at  any  time  during  parameter 
entry to execute a cycle with the existing parameters displayed. 
The only exception to this is during programming of the stored 
settings (1 – 9).
Quick cycle abort-Press the ADJ/SET knob at any time during 
the retherm cycle to return to the Idle State.
IV. OPERATION (cont’d)
-4-
User programming of the 9 most used cycle parameters.
Fast recall and cycle start of the pre-programmed cycle 
parameters. 
Very fast recall and cycle start of pre-programmed cycle 
#1 parameters.
Manual Setting Features
From the IDLE STATE (TIME is blinking) rotate the ADJ/
SET knob to adjust the retherm time. Press START to ac-
cept the currently displayed settings and begin the cycle 
or press ADJ/SET to set the currently displayed time and 
advance to the RETHERM TEMP setting. RETHERM is 
blinking. Rotate the ADJ/SET knob to adjust the retherm 
temperature. Press START to begin the cycle or press 
ADJ/SET to set the retherm temperature and advance 
to  the  HOLD  TEMP  setting.  HOLD  is  blinking.  Rotate 
ADJ/SET to adjust the hold temperature. Press START 
to execute the cycle or press ADJ/SET to re-adjust the 
three parameters. After a cycle is started press ADJ/SET 
at any time to abort the cycle and return to idle.
Pre-Programmed Cycle Feature
From  the  IDLE  STATE  (Time  Blinking)  press  and  hold 
ADJ/SET  for  3  seconds.  TIME  no  longer  blinks.  The 
current temperature display TEMP displays “P-1” and 
is blinking. TIME, RETHERM and HOLD display the pa-
rameters pre programmed for AUTO CYCLE  #1. Press 
START  to execute a retherm cycle with these parameters 
or rotate the ADJ/SET knob to select one of the other 
pre-programmed cycle settings (0–9) then press START 
. After a cycle is started press ADJ/SET at any time to 
abort the cycle and return to idle.
Programming The Pre-Programmed Cycles
From  the  IDLE  STATE  (Time  Blinking)  press  and  hold 
ADJ/SET  for  3  seconds.    TIME  no  longer  blinks.  The 
current temperature display TEMP displays “P-1” and 
is blinking. If necessary rotate ADJ/SET to the desired 
pre-programmed cycle “P-x”. Press and hold ADJ/SET 
for 3 seconds.  P-x no longer blinks and TIME is blinking. 
Rotate ADJ/SET to adjust the retherm time and press 
ADJ/SET to accept the retherm time. RETHERM is blink-
ing. Rotate ADJ/SET to adjust the retherm temperature 
and press ADJ/SET to accept the retherm temperature. 
HOLD is blinking.  Rotate ADJ/SET to adjust the hold 
temperature and press ADJ/SET to accept the hold tem-
perature. P-x has been updated to the currently displayed 
settings and P-x is again blinking. To program another 
location rotate ADJ/SET to the desired cycle # then press 
and hold ADJ/SET for 3 seconds. To return to IDLE press 
and release ADJ/SET. To start a cycle with the currently 
displayed settings press START.
Fast cycle Start Using Pre-programmed Setting #1
Press ADJ/SET. While holding ADJ/SET press START.
(see page 11 for Retherm & Holding Guide)