Insys GSM 4.2 I4 11-02-01-03-01.038 用户手册

产品代码
11-02-01-03-01.038
下载
页码 69
INSYS GSM 4.2 I4 
Functions and their configuration 
 
Dez-06 
            59 
4. 
If the remote terminal is busy, the device will redial according to the setting "Dial-
ing attempts". (see Chap. 4.1) 
The LED Status is flashing during the security callback process. 
The security callback number is independent from the caller number, which triggers the 
security callback. 
Outgoing calls from the device are not affected. 
 Activate security callback 
1. 
Start the HSComm and switch to the tab "Access control". 
2. 
Enter the requested number in the group "Callback number" 
 
Pertinent AT commands 
AT**PASS 
Password 
AT**DIAL 
Connection attempts 
AT**CALLBACK 
Target number security callback 
 
6.4 
History 
The current values from the internal history list are read out and displayed. The device 
records the following events continuously in a ring buffer.  
The ring buffer always contains the last 200 entries. The buffer will be deleted when re-
setting to factory settings. The entries will be displayed in chronological order on max. 
4 pages. 
Export as text 
The displayed data can be stored as text file. Have this data ready for technical support.