Problem
Possible Cause
Remedy
[4] Gear motor overload 
protector operates 
frequently or fuse 
blows frequently.
a)Power Supply
. Not within 
specifications.
. Refer to nameplate and 
correct.
b)Evaporator Assembly
. Bearings or auger 
worn out.
. Replace bearings or 
auger. See "V.F.. Upper 
Bearing Wear Check."
c) Bin Control
. Bad contacts.
. Check for continuity and 
replace.
. Actuator does not 
move freely.
. Clean actuator or replace 
bin control assembly.
d)Safety Switch and 
Relay
. Switch misaligned, 
contacts bad.
. Check and correct or 
replace.
e)Control Board
. Erratic operation of 
gear motor relay.
. See "II.D.4. Control Board 
Check Procedure."
4. Dispensing
Problem
Possible Cause
Remedy
[] No ice dispensed.
a) Power Supply
. "OFF" position.
. Move to "ON" position.
. Loose connection.
. Tighten.
3. Bad contacts.
3. Check for continuity and 
replace.
4. Not within 
specifications.
4. Refer to nameplate and 
correct.
b) Ice Storage
. No ice or little ice in 
storage bin.
. Make ice.
. Ice bridge or ice block 
formed.
. Melt ice, resupply with 
new ice.
3. Agitating motor 
defective.
3. Check, replace.
c) Ice Dispense Switch
. Opti Serve sensor 
defective. (OS only)
. See "5. Opti Serve (OS) 
Sensors."
. Bad contacts. (push 
button only)
. Check for continuity and 
replace.
d) Shutter Assembly
. Broken part.
. Check and replace.
. Open windings on 
solenoid.
. Check continuity and 
replace.
e) Dispense Gear Motor
. Thermal protector is 
tripped.
. Allow to cool.
. Gear motor winding 
open.
. Replace.
3. Bearing worn out.
3. Replace.
4. Wiring to gear motor. 4. Check for loose 
connection or open 
circuit, and replace wiring 
as needed.
5. Defective capacitor.
5. Replace.
f) Auger Mechanism
. Bad alignment of 
auger.
. Realign.
g) Control Board
. Defective.
. See "II.D.4. Control 