Hoshizaki DCM-750BAH-OS 补充手册

下载
页码 69
8
4. DCM-750BWH-OS
Note: We reserve the right to make changes in specifications and design without prior 
notice.
AC SUPPLY VOLTAGE
115/60/1 
COMPRESSOR
120 V
  10 RLA
  60 LRA
GEAR MOTOR
120 V
   3  FLA
 1/4 HP
AGITATING MOTOR
120 V
1.8  FLA (Total)
110 W
DISPENSING MOTOR
120 V
0.9  FLA
  55 W
OTHER
120 V
0.6  A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
PER 24 HR.
Temp.(°F)
    lbs./day ( kg/day )
70
* 744 337 719 326 708 321
    Reference without *marks
80
696 316 684 310 673 305
90
662 300 * 654 297 640 291
100
630 286 620 281 * 573 260
SHAPE OF ICE
Cubelet (Compressed Flake Ice)
ICE QUALITY
Approx.  88%, Ice  (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
95 lbs.
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC    W  (kWH/100 lbs.)
1383 (5.1)
1410 (4.5)
    POTABLE WATER
  89  (12)
78 (12)
    WATER - COOLED CONDENSER
606 (81.4)
 325 (49.7)
             gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
34-1/16" x 28-1/2" x 48-1/16"  (865 x 723 x 1221 mm)
EXTERIOR FINISH
Stainless Steel; Galvanized Steel (Rear)
WEIGHT
Net 375 lbs. ( 170 kg ), Shipping 405 lbs. ( 184 kg )
CONNECTIONS - ELECTRIC
Permanent Connection
                           - WATER SUPPLY
Inlet 1/2" FPT
Condenser Inlet      1/2" FPT
                           - DRAIN
Drain Pan 3/4" FPT
Condenser Outlet   1/2" FPT
Bin Drain 3/4" FPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/4 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
Water Regulating Valve
DISPENSER CONTROL SYSTEM
Photoelectric Sensor (Infrared)
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic,     Model RS55C1E-PAA
CONDENSER
Water-cooled, Double tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
(530 g)
DESIGN PRESSURE
High 460 PSIG,  Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Auto-reset Overload Protector
GEAR MOTOR PROTECTION
Manual reset Circuit Breaker 
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES - SUPPLIED
Spare Fuse
                           - REQUIRED
Legs
OPERATING CONDITIONS
VOLTAGE RANGE
 104  -  127 V
AMBIENT TEMP.
   45  -  100° F
WATER SUPPLY TEMP.
   45  -   90° F
WATER SUPPLY PRESSURE
   10  -  113 PSIG
WATER TEMP. (°F)
1 lb. 2.7 oz.
50
70
90
ENG F-013.0.1196