                                  G-0600/G-0800 CONTACTOR RELOCATION                    
                                                                       Installation Instructions 
 
 
 
Procedure: 
 
1.  Disconnect power supply to ice machine. 
2.  Remove old contactor. 
3.  IMPORTANT:  The replacement contactor is to be mounted on the component box bottom in an upright 
position using the clips and Mylar enclosed (do not remount contactor in its original side position). 
 
CAUTION:  Mylar must be installed to prevent electrical arcing to metal surfaces. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 