Lifebreath CAF-02-MB 用户手册
35
Water Pump Performance Specifications
16
14
12
10
8
6
4
2
0
Capacity on U.S. gpm
S2 and S4 Models
1 2 4 6 8 10 12
Total Head in Feet
L2 and L4 Models
1 2 4 6 8 10 12 14 16 18
20
16
14
12
10
8
6
4
2
0
Capacity on U.S. gpm
Total Head in Feet
This section of the manual is designed to be used
with the “Commissioning of Integrated Combo
System” worksheet. The worksheet is designed to
guide you through the start-up process in a logi-
cal, step by step method which should minimize
the work and time involved in having the system
meet the designed parameters.
with the “Commissioning of Integrated Combo
System” worksheet. The worksheet is designed to
guide you through the start-up process in a logi-
cal, step by step method which should minimize
the work and time involved in having the system
meet the designed parameters.
The following conditions are assumed:
•
The air filter is in place
•
All supply diffusers and return grilles are
fully open and unrestricted
fully open and unrestricted
•
Hot water is available to the furnace
•
The drain valve for the heating loop is
closed
closed
•
The shut off valves for the heating loop are
fully open
fully open
•
The throttling valve for the heating loop (if
applicable), is fully opened
applicable), is fully opened
•
Electrical power is available at the furnace
•
The return air temperature from the house
is approximately 70˚F (21˚C)
is approximately 70˚F (21˚C)
System Commissioning