REI MDC-900 用户手册

下载
页码 16
Version 4 
 
27 Feb 08 
Operational Control of the MDC-2100/MDC-900 
OSCOR Version 4.0  
Operational control of the MDC-2100 is provided by the OSCOR keypad using the normal 
OSCOR functional control.  For example, in the OSCOR SWEEP or ANALYZE modes, 
pressing the F1 button will toggle through all of the OSCOR inputs including the MDC-
2100 frequency bands.  Furthermore, in the SWEEP mode, pressing the RECALL button 
will display the OSCOR available inputs including the MDC inputs.  Some of the other 
normal OSCOR functions that are impacted by the MDC-2100 are described below.  
 
•  Press, F1 “INPUT” and repeat until “3-9GHz” is displayed in the lower left. 
•  Press, “SHIFT” (DATA FUNCTIONS area) and then “EXPAND” (CONTROL area). 
•  Press, F1 “Show All” once to select “Show All”.  Use the Control wheel to move the 
arrow to any signal you wish to analyze. 
•  Press, “Narrow” (CONTROL area) 2 or 3 times. 
•  Press, “Sweep/Analyze” (CONTROL area) to select “Analyze”. 
•  Reposition the arrow over the signal and press, “Narrow” to center the signal. 
•  Press, F4 “MDC Anlz”.  See Figure 6A
•  Press, F2 “3-9GHz” as often as needed to select the band with your signal. 
•  Press, F3 ”Fltr A & B” to select Filter A or Filter B.  Select the Filter with your signal. 
•  Press, F4 “Identify” once to identify the frequency.  Observe which way your signal 
moved.  The possible frequencies are displayed at top left.  Press, F4 again to return. 
•  Press, MENU “EXIT” to return to the normal menu. 
 
OSCOR Version 5.0  
Operational control of the MDC is provided by the OSCOR keypad using the normal 
OSCOR functional controls.  For example, in the OSCOR SWEEP or ANALYZE modes, 
pressing the F1 button will toggle through all of the OSCOR inputs including the MDC 
frequency bands.  Furthermore, in the SWEEP mode, pressing the RECALL button will 
display the OSCOR available inputs including the MDC inputs.  Some of the other normal 
OSCOR functions that are impacted by the MDC are described below.    
 
Signal identification Process: 
 
Viewing the entire spectrum from 3 to 21GHz; 
•  Select MDCA-all, as illustrated in Figure 5.  There are 4 methods you may use.   
o  Method 1.  Press RECALL (DATA FUNCTIONS area), scroll to “MDC-2100…. 
Filter A” and press RECALL (or MENU/VIEW SPAN then MENU/MANUAL 
MODE
).  
o  Method 2.  Press AUTO/MANUAL (MODE area - lower left by power light) then 
F2, then F1, etc.  This method picks from the same menu as above. 
o  Method 3.  Press F1/INPUT and repeat until you see MDCA-all displayed.   
o  Method 4.  Enter a frequency found in an MDCA window.  You must start from an 
OSCOR RF band (not INFRARED or AC VLF).     
o  Spans are recalled with the settings last used no matter which method is used.   
MDCA-all may not initially display.  If MDCA-1, MDCA-2 or MDCA-3 displays, 
press F4/MDC Anlz, then F1/Show All.   
REI   