Zephyr COK-E42SX 用户手册

下载
页码 23
www.zephyronline.com
4
In
s
ta
lla
ti
o
n
-
D
u
ct
wo
rk
C
a
lcula
tio
n
S
h
e
e
t
Duct pieces
Total
Equivalent number
length x used     =
3 1/4” x 10”
Rect.,
straight
1 Ft.           x (      )   =
Ft.  
7” Round,
straight
1 Ft.           x (      )   =
Ft.  
3 1/4” x 10”
Rect. 90
0
elbow
15 Ft.         x (      )   =
Ft.  
3 1/4” x 10”
Rect. 45
0
elbow
9 Ft.           x (      )   =
Ft.  
3 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft.         x (      )   =
Ft.  
3 1/4” x 10”
Rect.
wall cap
with damper
30 Ft.         x (      )   =
Ft.  
3 1/4” x 10”
Rect. to
6” round
transition
5 Ft.           x (      )   =
Ft.  
3 1/ 4” x 10”
Rect. to
6” round
transition
90
0
elbow
15 Ft.         x (      )   =
Ft.  
6” Round,
90
0
elbow
15 Ft.         x (      )   =
Ft.  
6” Round,
45
0
elbow
9 Ft.           x (      )   =
Ft.  
Ft.  
7” Round,
straight
1 Ft.           x (      )   =
Ft.  
Subtotal column 1 =
Duct pieces
Total
Equivalent number
length x used     =
6” Round
wall cap
with damper
30 Ft.         x (      )   =
Ft.  
7” Round
wall cap
with damper
30 Ft.         x (      )   =
Ft.  
7” Round,
90
0
elbow
15 Ft.         x (      )   =
Ft.  
7” Round,
45
0
elbow
9 Ft.           x (      )   =
Ft.  
Ft.  
Ft.  
Ft.  
6” Round,
roof cap
30 Ft.         x (      )   =
Ft.  
7” Round,
roof cap
30 Ft.         x (      )   =
Ft.  
Subtotal column 2 =
Subtotal column 1 =
Total ductwork      =
Maximum Duct Length:
For satisfactory air movement,
the total duct length of a 3 1/4” x 10” rectangular, 6” or 7”
diameter round ductshould not exceed 100 equivalent feet.
6” round to
3 1/4” x 10”
rect.
transition
1 Ft.           x (      )   =
Ft.  
6” round to
3 1/4” x 10”
rect.
transition
90
0
elbow
16 Ft.         x (      )   =
Ft.  
7” round to
3 1/4” x 10”
rect.
transition
8 Ft.           x (      )   =
Ft.  
7” round to
3 1/4” x 10”
rect.
transition
90
0
elbow
15 Ft.         x (      )   =
Ft.