Specifications
This appendix describes the physical characteristics of the hardware and
the recommended operating conditions.
PXI-8460 One Port and Two Port
Dimensions............................................. PXI 3U Module
100 by 160 mm
(3.94 by 6.30 in.)
Power requirement ................................. +5 VDC 500 mA typical
I/O connector.......................................... 9-pin D-Sub for each port
Operating environment
Component temperature.................. 0 to 55 °C
Relative humidity............................ 10% to 90%, noncondensing
Storage environment
Temperature .................................... –20 to 70 °C
Relative humidity............................ 10% to 90%, noncondensing
PXI-8461 One Port and Two Port
Dimensions............................................. PXI 3U Module
100 by 160 mm
(3.94 by 6.30 in.)
Power requirement ................................. +5 VDC 500 mA typical
I/O connector.......................................... 9-pin D-Sub for each port
(standard)
or
5-pin Combicon-style pluggable
DeviceNet screw terminal