Protect PV.500-MH Operating Instructions 
54 of 68 
80000043212 BAL 
 
7.2.5 Network 
Integration Configuration 
For network integration, you will need a free IP address for the 
COM server, the subnet mask plus the IP address for the gateway. 
This information can be obtained from your administrator if neces-
sary. 
  Start the "Digi Device Discovery" tool.  
  The tool searches the network for Digi modules. The modules 
found are displayed. If several units are found, please select 
the unit to be configured using the MAC address. This can be 
found on the Digi module sticker on the COM server. If no 
modules are detected, check your network and your firewall 
settings. Run the search again using "Refresh view". 
  Select the required unit. You can enter the necessary network 
parameters using the right mouse button + "Configure network 
settings". 
  Use "Save" and "Reboot" to apply the settings and complete 
the installation.  
  Exit the "Digi Device Discovery" tool.  
  You can use the "ping" command to test whether the COM 
server can be reached on the network. 
7.2.6 Configuration 
of 
the Virtual COM Port 
Communication with the COM server takes place via a virtual COM 
port, which is implemented by means of a RealPort driver. In order 
to do this, the RealPort driver needs to be installed and configured. 
  Start the RealPort driver installation process. For this purpose, 
the COM server must be connected to the network and the 
network parameters must be set. 
  The installation program searches the network for Digi mod-
ules. The modules found are displayed along with the config-
ured IP address and MAC address. If several units are found, 
please select the unit to be configured using the MAC address 
and select "Next". The MAC address can be found on the Digi 
module sticker on the COM server. If no modules are detected, 
check your network and your firewall settings. Run the search 
again using "Refresh view".  
  In the "Describe the Device" window, you can make RealPort 
settings. This is where you need to select the COM port via 
which the application is to communicate later. All other settings 
can be left as per the factory settings. 
  Select "Finish" to complete the installation. 
The application can communicate via the set COMx port with a 
baud rate of 115.2 kB as standard. 9600 kB is also possible as an 
alternative. Between these two transmission rates, the COM server 
has an autobaud detection function.