SERVICE (cont.)
SOLENOIDS
FIG. 16 SOLENOIDS
Location:
 
The solenoids are located inside the autofill box. 
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the white/violet, violet or blue wire and 
the white wire from the solenoid. 
3.  Connect the dispenser to the power source. Press 
the solenoid (water) switch, and with a voltmeter, 
check the voltage between the white wire, and either 
the blue, violet, or white/violet wire. The indication 
must be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 200 to 240 volts ac for two wire 200 or 240 volt 
models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the Wiring 
Diagrams and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If continuity is present as described,  refer to Fig. 17 
and reconnect the  wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
FIG. 17 SOLENOID TERMINALS
P1521
P1544
6.  Check the solenoid valve for coil action. Connect the 
dispenser to the power source. Press the solenoid 
(water) switch and listen carefully in the vicinity of 
the solenoid valve for a “clicking” sound  as the 
coil magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water inlet before the solenoid valve or, the 
solenoid valve may require inspection for wear, and 
removal of waterborne particles.
If the sound is not heard as described, rebuild or replace 
the solenoid valve.
Solenoid Valve Repair:
1.  Remove the wires from the solenoid valve to be 
repaired.
2.  Turn off the water supply to the dispenser.
3.  Remove the nut securing solenoid valve coil to the 
base.
4.  Remove guide, washer, o-ring, plunger/spring  and 
inspect for wear. Replace parts as required.
5.  Install new o-ring in the solenoid valve base.
6.  Install plunger/spring in the guide with spring to 
the bottom of the guide.
7.  Install guide with the plunger/spring into the solenoid 
valve base.
8.  Install washer on guide.
9.  Install coil with retainer on guide and secure with 
nut.
10. Refer to Fig. 17 and reconnect the wires.
#1 AFPO-2
& 3 #2 AFPO-2 
& 3 #3 AFPO-3 
ONLY
WHI from Main Harness
WHI to Solenoid #2
BLU from Solenoid
Switch #1
WHI to Solenoid #1
WHI to Pump #1
VIO from Solenoid 
Switch #2
WHI/VIO from 
Solenoid Switch #3
WHI to Main
Harness
WHI to Pump #3
41093 040408