feature also allows the machine to 
operate at reduced capacity, rather 
than shut down, when key safety limits 
are approached.
Chilled liquid reset — Reset can be 
accomplished manually or automatical-
ly from the building management sys-
tem. For a given capacity, reset allows 
operation at slower compressor 
speeds, saving energy when warmer 
chilled liquid can be used. 
Demand limiting — This feature lim-
its the power draw of the chiller during 
peak loading conditions. When incor-
porated into the Carrier Comfort 
Network
®
 building automation system, 
a red line command holds chillers at 
their present capacity and prevents any
other chillers from starting. If a load 
shed signal is received, the compres-
sors are unloaded to avoid demand 
charges whenever possible. 
Ramp loading — Ramp loading en-
sures smooth pulldown of liquid loop 
temperature and prevents a rapid 
increase in compressor power con-
sumption during the pulldown period.
Automated controls test — The 
test can be executed prior to start-up 
to verify that the entire control system 
is functioning properly.
365-day real time clock — This 
feature allows the operator to program 
a yearly schedule for each week, week-
ends, and holidays.
Occupancy schedules — Schedules 
can be programmed into the controller 
to ensure that the chiller operates 
when cooling is required and remains 
off when not needed by the tenants or 
process.
Extensive service menu — Unau-
thorized access to the service menu 
can be prevented through password 
protection. Built-in diagnostic capabili-
ties assist in troubleshooting and rec-
ommend proper corrective action for 
preset alarms, resulting in greater 
working time.
Alarm file — This file maintains the 
last 25 time-and date-stamped alarm 
messages in memory. This function re-
duces troubleshooting time and cost.
Alert file — This file maintains the 
last 25 alert messages in memory. This 
function provides prognostic informa-
tion and corrective actions that can 
avoid unit shutdown. 
Configuration data backup — 
Non-volatile memory provides 
protection during power failures and 
eliminates time consuming control 
reconfiguration.
Features/Benefits (cont)
23XRV – High Efficiency
Variable Speed Screw Chiller
Cooler Size*
30-32
35-37
40-42
45-47
50-52
55-57 
Condenser Size* 
30-32
35-37
40-42
45-47
50-52
55-57
Economizer Option
E
 – With Economizer
N – No Economizer
Voltage Code
3
 – 380-3-60
4 – 416-3-60
5 – 460-3-60
– 380/415-3-50
S – Special
R – Compressor
Not Used 
Drive Amps Amps
Code In† 
Out†
AA 440 442
BA 520 442
BB 520 520
Motor Code
P          T
Q          U
R          V
S    
CC 608 608
ASME
‘U’ Stamp
AHRI (Air Conditioning, Heating 
and Refrigeration Institute)
Performance  Certified
Model number nomenclature
*First number denotes frame size.
†Maximum limits only. Additional application
limits apply that may reduce these ampacities.
a23-1648
Quality Assurance
Certified to ISO 9001:2000
S
EISMI
C
OMPLIANT
*
* Meets IBC 2006, ASCE-7-05, CBC 2007, and OSHPD seismic requirements.