Kenwood TK-3160 用户手册

下载
页码 31
16
TK-3160
ADJUSTMENT
7.DQT TCXO
TEST CH: Center
Power mete
 ANT
Programming
Write
70 hex(K,M)
Balance
Dev meter
Software:KPG-82D
200 hex(K2,M2,K3,M3)
Writing
Oscilloscope
[Wide]
AG
[Narrow]
AF VTVM
40 hex(K,M)
120 hex(K2,M2,K3,M3)
8.DQT VCO
TEST CH: Low
Make the
Balance
Center
demodulation
Adjust
High
wave into
[Wide]
(3 points)
square waves
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
9.QT Deviation TEST CH: Low
0.8kHz
±40Hz
Adjust
Center
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
0.4kHz
±40Hz
PTT:ON
10.DQT Deviation TEST CH: Low
0.75kHz
±40Hz
Adjust
Center
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
0.35kHz
±40Hz
PTT:ON
11.Tone Deviation TEST CH: Center
3.0kHz
±100Hz
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
1.5kHz
±100Hz
12.DTMF Deviation TEST CH: Center
3.0kHz
±100Hz
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
1.5kHz
±100Hz
13.MSK Deviation TEST CH: Low
3.0kHz
±100Hz
Adjust
Center
[Wide]
High
(3 points)
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
1.5kHz
±100Hz
PTT:ON
14.BATT Detection
BATT terminal voltage:5.9V
Power meter
ANT
Write
BATT terminal
Writing
PTT:ON
DVM
BATT terminal
voltage:5.9V
[Wide]
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark