Use four holes (No.1 to No.4) to mount. 
Holes for 
mounting screw 
1
2
3
 
4
In case of using a 
center hole, use it in 
combination with the
holes of both ends. 
Holes for mounting screw 
 
Figure 4.5  Limitation of side-mounting 
(4) 
Limitation of bottom-mounting 
 
Use all four mounting holes on the bottom face. 
(5) Environmental 
temperature 
 
Temperature condition at installed in a cabinet is indicated with ambient temperature measured  
30 mm from the disk drive.  At designing the system cabinet, consider following points. 
•  Make a suitable air flow so that the DE surface temperature never exceed 60°C. 
•  Cool the PCBA side especially with air circulation inside the cabinet.  Confirm the cooling 
effect by measuring the surface temperature of specific ICs and the DE.  These measurement 
results must satisfy the temperature condition listed in Table 4.1. 
•  Keep the DE surface temperature at 50 °C or below to meet the condition for assuring an 
MTBF of 1,400,000 hours.  An air flow of 0.9 m/s or more is required at ambient temperature 
30 °C. 
 
Table 4.1 
Surface temperature check point 
No. Measurement 
point 
Max. temperature on 
package 
DE surface 
60 °C 
Read channel LSI 
82 °C 
VCM/SPM Driver 
100 °C 
4 HDC 
100 
°C 
5 MPU 
94 
°C 
52 