GE ZIS360NM 用户手册

下载
页码 72
– 3 –
Technical Data
**For model ZIS 36: WR55X10166.  Model ZIS 36D: WR55X10165.  Model ZIS 42:
WR55X10164.  Model ZIS 42D: WR55X10163.  Model ZIS 48: WR55X10162.
Model ZIS 48D: WR55X10158.
WARNING: Disconnect  power cord before
servicing.
Note: Reconnect all grounding devices.
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts, or washers used to
complete a path to ground are removed for
service, they must be returned to their original
positions and properly fastened.
Caution: To avoid personal injury when servicing
the condensing unit, stand on a ladder which will
give enough support to allow removal of the top
panel and safely allow access to service the unit.
Max Defrost Control
W/No Door Openings ............60 hrs @ 35 min
Evap Overtemperature Thermodisc ..............60 °F-45 °F
Light Thermostat .....................................140 °F-90 °F
Electrical Rating: 115 VAC 60 Hz.....................9.0 amp
Maximum Current Leakage............................ 0.50 mA
Maximum Ground Path Resistance ............ 0.14 ohms
Energy Consumption (HUMID) ................................. *
CONTROL POSITION 37-0 °F and
AMBIENT TEMPERATURE OF         70 °F               90 °F
Fresh Food, °F ....................... 36–46 .............. 37–48
Frozen Food, °F ..................... (-6)–6 .............. (-4)–3
Percent Running Time............. 41–46 .............. 53–55
To access the low-pressure side of the system,
install a WR86X0097 valve only on the process
tube extending from the compressor case.
Important Safety Notice:
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic, and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation
of this information, nor can it assume any liability in
connection with its use.
REFRIGERATION SYSTEM
Compressor ...............................................983 Btu/hr
Minimum Compressor Capacity
Vacuum .......................................... 26 inches
Minimum Equalized Pressure
@ 70 °F............................................ 72 PSIG
@ 90 °F.............................................88 PSIG
Refrigerant Charge (R134a) .............................14.50 oz
ELECTRICAL SPECIFICATIONS
NO LOAD PERFORMANCE
REFRIGERATION DIAGNOSIS
HMI Temperature Control..........................................**
Relay ....................................................WR07X10031
Overload ............................................... WR08X10015
Run Capacitor (15 uF) ............................. WR62X0080
Overtemperature Thermodisc Light .......... WR50X10035
Overtemperature Thermodisc Evaporator .. WR50X10036
Defrost Heater ....................................... WR51X10065
Drain Trough ASM .................................. WR17X11194
Condenser Fan Motor ............................ WR60X10083
Condenser Fan Blade ............................ WR60X10049
Evaporator Fan Motor ............................ WR60X10043
Evaporator Fan Blade ............................ WR60X10050
Main Board ........................................... WR55X10167
Thermistors (2-FF, 1-FZ, 1-EV) ............... WR55X10025
Damper Assembly Fresh Food ............... WR60X10085
Evaporator ............................................ WR84X10038
Compressor .......................................... WR87X10042
Condenser............................................. WR84X10037
Filter Dryer ............................................. WR86X0096
*For Models ZIS 36 & ZIS 36D: 51.2 kWh/mo.  Models ZIS 42 & ZIS 42D:
54.6 kWh/mo.  Model ZIS 48: 58.1 kWh/mo. Model ZIS 48D: 59.2 kWh/mo.
REPLACEMENT PARTS
Compressor
Process
Tube
High Pressure
(Do NOT use)
Evaporator
Heat Exchanger
Condenser
Suction
Tube
Condenser
Loop
Dryer
Overload
To Cabinet
Wiring
White
Orange
Black
Run
Capacitor
Green
(Ground)
To Cabinet
Wiring
White
Black
Overload
Green
(Ground)
Run Capacitor
Orange