GE TMW-800TC 用户手册

下载
页码 66
34
PRINTED CIRCUIT BOARD 
1. CIRCUIT CHECK PROCEDURE
1. Low voltage transformer check
The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage: 120V / Frequency: 60Hz
2. Voltage Check
- Key check point
- Check method
NOTE
1. Refer to Ciruit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source
voltage.
3. The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
NOTE
Each measure point must be measured with GND points.
Terminal Voltage
6-8
9-10
LOAD
DC 12V
AC 3.4V
NO LOAD
AC 25.8V
AC 4.0V
NO
CHECK POINT
REMARK
1
IC1 PIN 63, 64
5VDC
2
IC1 PIN 38
3
IC1 PIN 33 OR 34
T : 16.67ms(60Hz)
5V
0V
T : 250 ns(4MHz)
5V
0V
NO
MEASURE POINT
WAVE FORM
REMEDY
REMARK
1
MP1
DC 5V±0.25V
Replace Q8, ZD3, EC2
NO LOAD
2
MP2
DC 12V±2.0V
Replace D12, 13, R25, EC5, EC4
NO LOAD