ZIFI240PII –   GE Monogram Fresh-Food Refrigerator Module  
(Custom panel required)
ZIFS240PSS –  GE Monogram Fresh-Food Refrigerator Module  
(Stainless steel)
For answers to your Monogram,
®
 GE Profile
 or  
GE
®
 appliance questions, visit our website at  
GEAppliances.com or call GE Answer Center
®
  
service, 800.626.2000.
Listed by 
Underwriters 
Laboratories
Dimensions and Specifications (in inches)
Installation Space
The cutout depth must be 24"
The cutout dimensions shown allow for a full door swing and access 
to the pull-out racks when installed as a built-in.
•  The Fresh-Food Refrigerator can be free-standing.
•  The stainless steel model ZIFS240PSS can be installed flush with 
standard cabinetry. ZIFI240PII with custom panel will project  
forward 1-3/4" of adjacent 24" deep base cabinets.
• Note: Door swing is not reversible.
Additional Specifications:
•  A 120 volt 60Hz., 15 or 20 amp power supply is required. An  
individual property grounded branch circuit or circuit breaker is  
recommended. Install a properly grounded 3-prong electrical  
receptacle recessed into the back wall as shown. Electrical  
must be located on rear wall as shown. Note: GFI (ground fault 
interrupter) is not recommended.
34-1/2"-35"
24" Min.
23-3/4" 
34-1/2"
23-3/4" Stainless Steel 
Models
24-7/8" Framed Models
1-1/2" 
Locate Outlet 
9" 
Max.
10-1/2" 
Depth Including 
Handle:
26" Stainless Steel
Models Only
23-3/4" Min. 
Note: If installing between frameless 
cabinets, a 1/2" wide filler strip or side panel
may be required. The filler strip will act as a 
spacer between the door case and adjacent cabinet 
and will prevent interference with cabinet door swing. 
The width of the opening must include filler panels.
Product Clearances
16" Minimum
110˚
Wall
24"
Cabinet
14" Minimum
110˚
Wall
24"
Cabinet
All models are factory set for a 110° door swing.
For a minimum 90° door swing:
•  Allow 4" min. clearance to wall on the hinge side for Stainless  
Steel models.
•  Allow 4-1/2" min. clearance to wall on the hinge side for models 
with a custom panel and custom handle.
For a full 110° door swing:
•  Allow 14" min. clearance to wall on the hinge side for Stainless 
Steel models.
•  Allow 16" min. clearance to wall on the hinge side for models with  
a custom panel and custom handle.
Stainless Steel  
Models
Models with a Custom 
Door Panel
Specification Revised 7/05