Amana XRSS267BB 用户手册

下载
页码 320
24
Before Calling Service
ICE & WATER
 
 
 
TOPIC POSSIBLE 
CAUSE 
SOLUTION 
Ice maker is not producing 
ice (some models-continued) 
Improper water valve was installed. 
Check water connection procedure in your 
Installation 
Instructions. Self-piercing and 
3
/
16
” saddle valves cause  
low water pressure and may clog the line over time. The 
manufacturer is not responsible for property damage  
due to improper installation or water connection.
 
Plastic tubing was used to complete  
water connection. 
The manufacturer recommends using copper tubing  
for installation. Plastic is less durable and can cause 
leakage. The manufacturer is not responsible for 
property damage due to improper installation or  
w ater connection.
 
Unit is leaking w ater 
Improper water valve  was installed. 
Check water connection procedure in your 
Installation 
Instructions
. Self-piercing and 
3
/
16
” saddle valves cause  
low water pressure and may clog the line over time. The 
manufacturer is not responsible for property damage 
due to improper installation or w ater connection.
 
Water pressure is low. 
Water pressure must be between 20 to 100 pounds per 
square inch to function properly. A minimum pressure of  
35 pounds per square inch is recommended for units with 
water filters. 
Ice forms in inlet tube to  
ice maker
 
Freezer temperature is too high. 
See the controls section in your Owner’s Manual for 
assistance on how to adjust your controls. Freezer is 
recommended to be between 0 to 2°F (-18 to –17°C). 
Water pressure is low. 
Water pressure must be between 20 to 100 pounds per 
square inch to function properly. A minimum pressure of  
35 pounds per square inch is recommended for units with 
water filters. 
Improper water valve was installed. 
Check water connection procedure in your 
Installation 
Instructions
. Self-piercing and 
3
/
16
” saddle valves cause  
low water pressure and may clog the line over time. The 
manufacturer is not responsible for property damage 
due to improper installation or w ater connection.
 
Water inlet tubing has kinks. 
Turn off water supply and remove kinks. If kinks cannot be 
removed, replace tubing. 
Water flow  is slow er  
than normal 
Water filter is clogged or needs to  
be changed. 
Change water filter. 
Refrigerator has been recently installed 
Water supply in holding tank has  
been depleted. 
Allow approximately 12 hours for water in holding tank  
to chill. 
Dispenser water is not cold 
Water has settle into water lines outside 
holding tank and has warmed to  
room temperature. 
Discard first glass of water and refill.