SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Compressor not running.
Fuse blown or circuit breaker tripped.
Replace fuse or reset circuit 
breaker.
Power cord unplugged.
Plug in power cord.
Thermostat set too high.
Set thermostat to lower 
temperature.
Cabinet in defrost cycle.
Wait for defrost cycle to finish.
Condensing unit runs for
Excessive amount of warm product
Allow adequate time for 
long periods of time.
placed in cabinet.
product to cool down.
Prolonged door opening or door ajar.
Ensure doors are closed when 
not in use.  Avoid opening 
doors for long periods of time.
Door gasket(s) not sealing properly.
Ensure gaskets are snapped in
completely.  Remove gasket 
and wash with soap and water.  
Check condition of gasket and 
replace if necessary.
Dirty condenser coil.
Clean the condenser coil.
Evaporator coil iced over.
Unplug unit and allow coil to 
defrost.  Make sure thermostat 
is not set too cold.  Ensure that 
door gasket(s) are sealing 
properly.
Cabinet temperature is
Thermostat set too warm.
Set thermostat to lower 
too warm.
temperature.
Blocking air flow.
Re-arrange product to allow for
proper air flow.  Make sure 
there is at least four inches of 
clearance from evaporator.
Excessive amount of warm product
Allow adequate time for 
placed in cabinet.
product to cool down.
Fuse blown or circuit breaker tripped.
Replace fuse or reset circuit 
breaker.
Dirty condenser coil.
Clean the condenser coil.
Prolonged door opening or door ajar.
Ensure doors are closed when 
not in use.  Avoid opening 
doors for long periods of time.
Evaporator coil iced over.
(see above)
Cabinet is noisy.
Loose part(s).
Locate and tighten loose 
part(s).
Tubing vibration.
Ensure tubing is free from 
contact with other tubing or 
components.