8. MAINTENANCE, TROUBLESHOOTING 
 8-5
8.5.4 Sounder 
Requires Network Sounder ETR-6/10N/30N. 
Sounder troubleshooting 
If… But…  Then… 
you selected a sounder 
display with the DISP key 
picture does not appear 
• 
check that the network 
sounder’s signal cable is firmly 
fastened. 
• 
Check that sounder source is 
correct. 
• 
check that the network sounder 
is plugged in. The LED on the 
network sounder should flash 
every second. 
marks and characters 
appear 
picture does not appear 
• 
check for loosened transducer 
connector. 
the picture appears   
zero line does not appear   
• 
the picture is shifted. Confirm 
shift setting. 
picture sensitivity is too low 
— 
• 
check gain setting, if using 
manual operation. 
• 
marine life or air bubbles may 
be clinging to transducer face. 
• 
bottom may be too soft to 
return a suitable echo. 
the depth indication is not 
displayed 
— 
• 
adjust gain and range to display 
the bottom echo (in reddish 
brown), if you are using the 
manual sounder mode. 
noise or interference shows 
on the display 
— 
• 
check to be sure the transducer 
cable is not near ship’s engine.
• 
check the ground. 
• 
other video sounders of the 
same frequency as yours may 
be operating near you. 
the water temperature graph 
appears  
data is wrong 
• 
check that sensor cable is 
tightly fastened.